09 PREVENTIVE AND CORRECTIVE MAINTENANCE
4.
Inside TEU1 or COU1 remove the busbar connectors in the sequence
shown in Fig. 9-20.
CAUTION
A busbar connector weighs approximately
10 kg
.
Figure 9-20 Busbar connector removal sequence in TEU1 or COU1
5.
Remove the grounding sets.
6.
Check that the LEDs are lit.
7.
Check that tools and foreign objects are not left inside the cabinets.
8.
Close and lock the doors.
9.
Check that the power operating mode (POM) of the drive corresponds
to the busbar connectors fitted.
1
2
3
4
5
6