Actual signals and parameters
101
Parameters in the Long parameter mode
Index
Name/Selection
Description
Def
-4 = DI4(INV)
See selection DI1(INV).
-5 = DI5(INV)
See selection DI1(INV).
2110
TORQ BOOST CURR
Defines the maximum supplied current during torque boost. See parameter
2101
START FUNCTION.
100%
15
…300%
Value in percent
2112
ZERO SPEED DELAY
Defines the delay for the Zero speed delay function. The function is useful in
applications where a smooth and quick restarting is essential. During the
delay the drive knows accurately the rotor position.
No Zero speed delay
With Zero speed delay
Speed
Speed
Modulator switched
Modulator remains live. Motor
off: Motor coasts to
is decelerated to true 0
stop.
speed.
Zero speed
Zero speed
t
Delay
t
Zero speed delay can be used, for example, with jogging function (parameter
1010
JOGGING SEL).
No Zero speed delay
The drive receives a stop command and decelerates along a ramp. When the
motor actual speed falls below an internal limit (called Zero speed), the
modulator is switched off. The inverter modulation is stopped and the motor
coasts to standstill.
With Zero speed delay
The drive receives a stop command and decelerates along a ramp. When the
actual motor speed falls below an internal limit (called Zero speed), the zero
speed delay function activates. During the delay the functions keeps the
modulator live: The inverter modulates, motor is magnetized and the drive is
ready for a quick restart.
0.0 = NOT
SEL
0.0 = NOT SEL
0.0
…60.0 s
Delay time. If parameter value is set to zero, the Zero speed delay function is
disabled.
22 ACCEL/DECEL
Acceleration and deceleration times
2201
ACC/DEC 1/2 SEL
Defines the source from which the drive reads the signal that selects
between two ramp pairs, acceleration/deceleration pair 1 and 2.
Ramp pair 1 is defined by parameters
2202
ACCELER TIME 1,
2003
DECELER TIME 1 and
2204
RAMP SHAPE 1.
Ramp pair 2 is defined by parameters
2205
ACCELER TIME 2,
2206
DECELER TIME 2 and
2207
RAMP SHAPE 1.
5 = DI5
0 = NOT SEL
Ramp pair 1 is used.
1 = DI1
Digital input DI1. 1 = ramp pair 2, 0 = ramp pair 1.
2 = DI2
See selection DI1.
3 = DI3
See selection DI1.
4 = DI4
See selection DI1.
5 = DI5
See selection DI1.
-1 = DI1(INV)
Inverted digital input DI1. 0 = ramp pair 2, 1 = ramp pair 1.
-2 = DI2(INV)
See selection DI1(INV).
Summary of Contents for ACS150 series
Page 4: ......
Page 5: ......
Page 15: ...14 Safety ...
Page 19: ...18 Introduction to the manual ...
Page 39: ...38 Planning the electrical installation ...
Page 51: ...50 Installation checklist ...
Page 57: ...56 Start up and control with I O ...
Page 69: ...68 Control panel ...
Page 79: ...78 Application macros ...
Page 160: ...L Q M 0 I II D I II I I ro I m D en m D D Q Q f 3AFE68633931 A 0 Frame size R2 IP20 INEMA 1 ...
Page 161: ...ji 4 I 5 I 6 4 J ...
Page 162: ......
Page 163: ...160 Dimension drawings ...
Page 169: ...166 Appendix Process PID control ...
Page 171: ...168 ...