Application macros
User macros
In addition to the standard application macros, it is possible to create three user
macros. The user macro allows the user to save the parameter settings, including
group
99 START-UP DATA
, into the permanent memory and recall the data at a later
time. The panel reference is also saved if the macro is saved and loaded in local
control. The remote control setting is saved into the user macro, but the local control
setting is not.
The steps below show how to create and recall User macro 1. The procedure for the
other two user macros is identical, only the parameter
9902
APPLIC MACRO values
are different.
To create User macro 1:
• Adjust the parameters.
• Save the parameter settings to the permanent memory by changing parameter
9902
APPLIC MACRO to -1 (USER S1 SAVE).
MENU
• Press
ENTER
to save.
To recall User macro 1:
• Change parameter
9902
APPLIC MACRO to 0 (USER S1 LOAD).
MENU
• Press
ENTER
to load.
Note:
User macro load restores the parameter settings including group
99 START-
UP DATA
.
Check that the settings correspond to the motor used.
Hint:
The user can for example switch the drive between three motors without
having to adjust the motor parameters every time the motor is changed. The user
needs only to adjust the settings once for each motor and then to save the data as
three user macros. When the motor is changed, only the corresponding user macro
needs to be loaded, and the drive is ready to operate.
Summary of Contents for ACS150 series
Page 4: ......
Page 5: ......
Page 15: ...14 Safety ...
Page 19: ...18 Introduction to the manual ...
Page 39: ...38 Planning the electrical installation ...
Page 51: ...50 Installation checklist ...
Page 57: ...56 Start up and control with I O ...
Page 69: ...68 Control panel ...
Page 79: ...78 Application macros ...
Page 160: ...L Q M 0 I II D I II I I ro I m D en m D D Q Q f 3AFE68633931 A 0 Frame size R2 IP20 INEMA 1 ...
Page 161: ...ji 4 I 5 I 6 4 J ...
Page 162: ......
Page 163: ...160 Dimension drawings ...
Page 169: ...166 Appendix Process PID control ...
Page 171: ...168 ...