Actual signals and parameters
102
Parameters in the Long parameter mode
Index
Name/Selection
Description
Def
-3 = DI3(INV)
See selection DI1(INV).
-4 = DI4(INV)
See selection DI1(INV).
-5 = DI5(INV)
See selection DI1(INV).
2202
ACCELER TIME 1
Defines the acceleration time 1, that is the time required for the speed to
change from zero to the speed defined by parameter
2008
MAXIMUM FREQ.
- If the speed reference increases faster than the set acceleration rate, the
motor speed follows the acceleration rate.
- If the speed reference increases slower than the set acceleration rate, the
motor speed follows the reference signal.
- If the acceleration time is set too short, the drive automatically prolongs the
acceleration in order not to exceed the drive operating limits.
Actual acceleration time depends on parameter
2204
RAMP SHAPE 1
setting.
5.0 s
0.0
…1800.0 s
Time
2203
DECELER TIME 1
Defines the deceleration time 1, that is the time required for the speed to
change from the value defined by parameter
2008
MAXIMUM FREQ to zero.
- If the speed reference decreases slower than the set deceleration rate, the
motor speed follows the reference signal.
- If the reference changes faster than the set deceleration rate, the motor
speed follows the deceleration rate.
- If the deceleration time is set too short, the drive automatically prolongs the
deceleration in order not to exceed drive operating limits.
If a short deceleration time is needed for a high inertia application, the drive
should be equipped with a brake resistor.
Actual deceleration time depends on parameter
2204
RAMP SHAPE 1
setting.
5.0 s
0.0
…1800.0 s
Time
2204
RAMP SHAPE 1
Selects the shape of the acceleration/deceleration ramp 1. The function is
deactivated during emergency stop (
2109
EMERG STOP SEL) and jogging
(
1010
JOGGING SEL).
0.0 = LINEAR
0.0 = LINEAR
0
.0…1000.0 s
0.0 s: Linear ramp. Suitable for steady acceleration or deceleration and for
slow ramps.
0.1…1000.0 s: S-curve ramp. S-curve ramps are ideal for conveyors carrying
fragile loads, or other applications where a smooth transition is required
when changing from one speed to another. The S-curve consists of
symmetrical curves at both ends of the ramp and a linear part in between.
A rule of thumb
Speed
Linear ramp: Par. 2204 = 0 s
A suitable relation between the
Max
ramp shape time and the
acceleration ramp time is 1/5.
S-curve ramp:
Par. 2204 > 0 s
t
Par. 2202
Par. 2204
Summary of Contents for ACS150 series
Page 4: ......
Page 5: ......
Page 15: ...14 Safety ...
Page 19: ...18 Introduction to the manual ...
Page 39: ...38 Planning the electrical installation ...
Page 51: ...50 Installation checklist ...
Page 57: ...56 Start up and control with I O ...
Page 69: ...68 Control panel ...
Page 79: ...78 Application macros ...
Page 160: ...L Q M 0 I II D I II I I ro I m D en m D D Q Q f 3AFE68633931 A 0 Frame size R2 IP20 INEMA 1 ...
Page 161: ...ji 4 I 5 I 6 4 J ...
Page 162: ......
Page 163: ...160 Dimension drawings ...
Page 169: ...166 Appendix Process PID control ...
Page 171: ...168 ...