Chapter 79 Networked AV Mode
XGS2220 Series User’s Guide
560
79.7 SYSTEM
The following sections introduces the
SYSTEM
screens.
79.8 What You Can Do
• Use the
Cloud Management
screen (
) to view NCC Connection status and
enable/disable NCC Discovery.
• Use the
General Setup
screen (
) to configure general settings such as the
system name and time.
• Use the
IP Setup
screen (
) to configure the default gateway device, the
default domain name server and add IP domains.
• Use the
Logins
) to change the system password, configure
passwords for up to four users and set their privilege level.
Temperature
(C/F)
BOARD/MAC
/
PHY
refers to the location of the temperature sensor on the Switch printed circuit
board.
Status
This field displays
Normal
for temperatures below the threshold and
Error
for those above.
Current
This shows the current temperature at this sensor.
MAX
This field displays the maximum temperature measured at this sensor.
MIN
This field displays the minimum temperature measured at this sensor.
Threshold
This field displays the upper temperature limit at this sensor.
Fan Speed
(RPM)
A properly functioning fan is an essential component (along with a sufficiently ventilated, cool
operating environment) in order for the device to stay within the temperature threshold. Each
fan has a sensor that is capable of detecting and reporting if the fan speed falls below the
threshold shown.
Status
Normal
indicates that this fan is functioning above the minimum speed.
Error
indicates that this
fan is functioning below the minimum speed.
Current
This field displays this fan's current speed in Revolutions Per Minute (RPM).
MAX
This field displays this fan's maximum speed measured in Revolutions Per Minute (RPM).
MIN
This field displays this fan's minimum speed measured in Revolutions Per Minute (RPM). "<41" is
displayed for speeds too small to measure (under 2000 RPM).
Threshold
This field displays the minimum speed at which a normal fan should work.
Voltage(V)
The power supply for each voltage has a sensor that is capable of detecting and reporting if the
voltage falls out of the tolerance range.
Status
Normal
indicates that the voltage is within an acceptable operating range at this point;
otherwise
Error
is displayed.
Current
This is the current voltage reading.
MAX
This field displays the maximum voltage measured at this point.
MIN
This field displays the minimum voltage measured at this point.
Threshold
This field displays the percentage tolerance of the voltage with which the Switch still works.
Table 322 MONITOR > System Information (continued)
LABEL
DESCRIPTION
Содержание XGS2220 Series
Страница 27: ...27 PART I User s Guide ...
Страница 56: ...56 PART II Technical Reference ...
Страница 154: ...Chapter 20 Cloud Management XGS2220 Series User s Guide 154 Figure 105 SYSTEM Cloud Management ...
Страница 309: ...Chapter 45 Multicast XGS2220 Series User s Guide 309 Figure 226 MVR Group Configuration Example View ...
Страница 467: ...Chapter 68 Policy Rule XGS2220 Series User s Guide 467 Figure 343 Policy Example ...
Страница 555: ...Chapter 78 MAINTENANCE XGS2220 Series User s Guide 555 Figure 413 MAINTENANCE Tech Support Download ...
Страница 562: ...Chapter 79 Networked AV Mode XGS2220 Series User s Guide 562 Figure 418 SYSTEM Cloud Management ...
Страница 616: ...616 PART III Troubleshooting and Appendices ...