If this trip can be carried out without any problems and without any fault messages, a normal trip can
be made as the next step.
If fault messages appear, an error list is available in the
“
Diagnose
”
chapter together with the
corresponding error causes
8.7
Optimisation of the startup and drive behaviour
The "SPD_KP" (ampli
fi
cation) parameter can be used to optimise the setting of the speed controller
acting during travel. The parameter can be changed in the
Control/SPD_KP
menu.
Control
|
-
"
SPD_KP
1.00
|
-
"
0.95
Speed controller basic
gain
You can generally set the speed control by changing the factor for the basic ampli
fi
cation ("SPD_KP").
If signi
fi
cant control deviations occur during the trip (especially during acceleration and deceleration),
(see Fig.), the ampli
fi
cation has been set too low. In this case, increase the factor for ampli
fi
cation
("SPD_KP").
´
Control deviations when the ampli
fi
cation is set too low
blue
Set-value - travel speed
red
Actual-value - travel speed
If the motor is noisy or starts vibrating (see
fi
gure), ampli
fi
cation is set too high. In this instance, the
factor for ampli
fi
cation ("SPD_KP") should be reduced.
Control deviations when the ampli
fi
cation is set too high
blue
Set-value - travel speed
red
Actual-value - travel speed
Optimum setting of the speed controller
The following procedure is recommended to obtain an optimum setting of the speed controller:
Increase the parameter
Loop control/SPD_KP
until the motor causes noises/vibrations when starting
up.
Decrease the parameter
Loop control/SPD_KP
until the motor causes no noises/vibrations when
starting up.
Translation of the original operating instructions
ZETADYN 4C
Start-up
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
58/204
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...