Velocity Mode (Velocity Mode [pv])
Velocity Mode
•
Position Mode (Position Mode [pp]
Position Mode
The used mode can be set in the menu "CAN/MODE" of the ZETADYN 4C Generally the mode is sent
from the control system to the ZETADYN 4C shortly before start-up. Therefor you have to set the
operation mode in the control system.
When the ZETADYN 4C is operated in position mode, the shaft-encoder has to be connected to the
same bus as the ZETADYN 4C.
The control system transmits the travel speed to the ZETADYN 4 before every drive. If the transmitted
speed couldn't be reached, the ZETADYN 4 initiates a pointed arch drive. Therefor the maximum
speed has to be entered in the control system.
10.2.1.8
Command- and Statusbits of the recorder
•
Position Mode [pp] C&S / Velocity Mode [pv] C&S
•
C = Command = command from the control to the frequency inverter
•
S = Status = Status of the ZETADYN 4 as reaction to a previous command from the control
Status- / Commandbit
Description
Comment
CSwO
Command Switch On
CEVo
Command Enable Voltage
CQSt
Command Quick Stop
CEOp
Command Enable Operation
CFaR
Command Fault Reset
CNSp
Command New Setpoint
only active in position mode
Translation of the original operating instructions
ZETADYN 4C
Serial communication
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
68/204
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...