General conditions required for an encoder alignment without load:
•
The installation and motor data must be con
fi
gured
•
Load-free operation (ropes must be removed from the traction sheave)
•
Brake monitoring must be activated corresponding to the number and type of brakes in use (
Monitoring/BR
menu)
•
Contactor monitoring must be con
fi
gured according to the type of contact for monitoring (
Monitor-
ing/CO
menu)
General conditions required for an encoder alignment closed brake:
•
The installation and motor data must be con
fi
gured
•
It must be ensured that the brake does not open during the calibration (disconnect brake)
•
Brake monitoring must be activated corresponding to the number and type of brakes in use (
Monitoring/BR
menu)
•
Contactor monitoring must be con
fi
gured according to the type of contact for monitoring (
Monitor-
ing/CO
menu)
16.2.1
Load-free alignment SSI-Encoder
While the SSI encoder is being calibrated, the ZETADYN 4 energises the motor with direct current. In
the process, the rotor jumps to the centre of the nearest magnetic pole. In this rotor position, the SSI
encoder must be manually calibrated to its zero point. In order to make assembly easier, it is
recommended that you connect the SSI encoder to the ZETADYN 4 prior to assembly and calibrate
the offset value "0" (value in the
ENCODER calibration/ENC_POS
menu). Subsequently mount the
SSI encoder, if possible without any twisting, in the position in which the locking screw is easily
accessible.
Information
The calibration should always be done twice. Any inaccuracy in the 1st calibration is detected by the
2nd calibration and can be corrected.
If the SSI encoder terminal screw is not accessible in the "ENC_POS = 0" position, the SSI encoder
can be calibrated to the value of any pole pair (see table).
Pole pair
ZETATOP-motor
SM 160 / SM200 / SM225 / SM250
ZETASYN-motor
SM700 / SM860
1
0
0
2
819
546
3
1638
1092
4
2458
1638
5
3277
2185
6
4096
2731
7
4915
3277
8
5734
3823
9
6554
4369
10
7373
4915
11
-
5461
12
-
6007
13
-
6554
14
-
7100
15
-
7646
Translation of the original operating instructions
ZETADYN 4C
Special functions
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
153/204
1
6
Special
functions
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...