13.2.3
Parameterisation
(1) The following prerequisites must be present:
The direction of travel of the car is downwards with
Standard
DCP
24V signal on input con
fi
gured to
"RV2"
Command byte 1, Bit 4 has 1-sig-
nal
Detection of voltage drop
Con
fi
gure digital input in the
Control system
menu to
PARA2
.
Control
|
-
"
f_I08
PARA2
|
-
"
PARA2
Function I_08
In case of a voltage drop (power failure), the con
fi
gured input with 24 VDC is actuated in order to
inform the frequency inverter that a switchover must be made to parameter set 2.
(3) Inform the open loop control about the permissible direction of travel (optional):
Standard
DCP
Con
fi
gure digital output in the
Control system
menu to
Evac. Dir.
Status byte 2, Bit 2 = 0
R
Car is lighter than coun-
terweight
Evacuation trip will be carried out upwards!
Status byte 2, Bit 2 = 1
R
Car is heavier than
counterweight
Evacuation trip will be carried out downwards!
Control
|
-
"
f_O4
Evac.Dir
|
-
"
Evac.Dir
Function O4
Contact open
R
Car is lighter than counterweight
Evacuation trip will be carried out upwards!
Output closed
R
Car is heavier than counter-
weight
Evacuation trip will be carried out downwards!
(4) Evacuation type default
Con
fi
gure the parameter
F_PARA2 = UPS
in the
Parameter set 2
menu.
Parameter set 2
|
-
"
F_PARA2 UPS
|
-
"
UPS
Function parameter set 2
(5) Presetting the stator resistor in synchronous motors
Con
fi
gure the synchronous motor's stator resistor in the
Parameter set 2 / RS_UPS
menu
Parameter set 2
|
-
"
RS_UPS
1.00
Ohm
|
-
"
1.00
Stator resistance (UPS
(6) Limit motor current
Limit the motor current by entering the available UPS power in the
"Parameter set 2/P_UPS"
menu.
Parameter set 2
|
-
"
P_UPS
1.0
kW
|
-
"
1.0
Max. load of the UPS
Translation of the original operating instructions
ZETADYN 4C
Emergency evacuation
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
123/204
1
3
Emergency
evacuation
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...