Test step 2
1. Disconnect the signal cable at a monitor input and short circuit the monitor input with the internal
24V DC voltage source of the ZETADYN.
2. Perform test run.
3. The error message "380 BR:Start Error" (monitor function "NOC") or "582 BR:T2 too small"
(monitor function "NCC") must be output already at the start, otherwise the monitor is faulty.
4. The ZETADYN locks, no further travel is possible.
5. Remove short-circuit and re-connect the signal cable.
6. Repeat the test run to check the lock. A new run may not be possible, the ZETADYN is still locked.
7. Release the lock by setting the
“
Monitoring / UNLOCK = On
”
parameter (see display).
8. Start new run, this must take place without errors.
Monitors
|
-
"
UNLOCK
On
|
-
"
On
Unlock encoder
Repeat test step 2 for every monitor input.
16.13
Autotune function
With asynchronous motors the motor data are often unavailable or the data speci
fi
ed on the name
plate are not correct. The optimum operating data for the motor can be determined with the Autotune
function.
Information
Make sure that the cabin is empty whilst performing a measurement with the Autotune function,
otherwise the measuring result will be incorrect.
Determining the operating data with the Autotune function
Travel
|
-
"
V_3
0.95 m/s
|
-
"
0.95 m/s
High travel speed
Standard or DCP actuation:
When you use the standard or the DCP activation, reduce V_3 to 75% of V*
in the
Travel
menu.
CAN actuation:
If you use CAN activation, reduce the travel speed manually to 75% with the
control.
Mot - - - - - - - - - - - -
04
zzz
_ _ _ _ _ _ _+0 %
real: 0rpm 0V
prog: 0rpm +0.0A
Move down with empty cabin. Check in the
INFO menu/page 04
whether
motor voltage is < 320 V.
If the motor voltage is > 320 V, reduce V_3 further in the
Travel
menu.
Repeat the steps until the motor voltage is < 320 V.
LCD & password
->Motor name plate
Encoder & BC
System data
Select menu
"Motor name plate"
Motor name plate
|
-
"
ASM_ID
OFF
|
-
"
Select parameter
"ASM_ID"
Enter "ASM_ID=On"
Translation of the original operating instructions
ZETADYN 4C
Special functions
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
180/204
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...