Error no.
Error text
Error cause
M S
550
MOT: Overload !
Error:
Motor current exceeds the value max for time Tmax
Remedy:
Check the parameter in the "Motor name plate" menu,
Check the weight compensation
Check the brake switching function
●
●
560
V > VZ
Error:
Actual speed exceeds the speci
fi
ed nominal speed for readjustment
when readjusting.
Info:
inverted Function
Error is displayed if entered in mask
At
CONFIG: 31:KL_IO
the function is entered in the mask automatically.
●
570
PFU: Fault
Error:
Monitor contact of the power feedback unit opens during ZETADYN 4
operation
Remedy:
Check connection of the feedback unit function monitor,
Check feedback unit function monitor
●
571
PFU:Stdby remains in
place
Error:
PFU is not yet active 1 s after start of travel
●
575
MOT: Temp. -Alarm
Error:
Motor temperature monitor triggered during the trip (error evaluation
only if error no. 575 is entered in the mask function)
Remedy:
Check the parameter in the "Motor name plate" menu,
check the motor's duty cycle,
check the motor for winding short,
Check rotary encoder,
Check the brake function
●
●
582
BR:T2 too small
Error:
Brake does not open within time T2 (only active if brake monitor is
switched on)
Remedy:
Check the brake triggering,
check the brake opening time,
check the con
fi
gured brake opening time "T_2" in the "Start" menu and
increase if necessary
●
583
BR: Fault Travel
Error:
Brake monitoring contacts triggered during travel
Remedy:
Check the brake triggering,
check the monitoring contacts,
check the power supply of the brakes
Info:
inverted Function
If entered in the mask, the error leads to immediate stop of travel
●
●
584
BR: Fault Travel
Error:
Brake monitoring contacts triggered during travel
Fault message at end of travel with additional information = 0:
Brake monitor contacts have switched during travel but the brake was not
closed
Fault message without immediate interruption of travel and additional informa-
tion
≠
0:
Brake was closed during travel
Additional information:
Indicates consequential fault
Remedy:
Check the brake triggering,
check the monitoring contacts,
check the power supply of the brakes
●
●
585
BR: T5 too small
Error:
Brake does not close within time T5 (only active if brake monitor is
switched on)
Remedy:
Check the brake triggering,
check the brake closing time,
check the con
fi
gured brake opening time "T_5" in the "Stop" menu and
increase if necessary
●
586
BR: Stop-Error
Fault:
Monitoring contact of the brake brie
fl
y signals "Brake closed and then
"Brake open" again longer as the time T5 (only active with the brake monitor
switched on)
Remedy:
Check the brake triggering,
check the brake closing time,
check the con
fi
gured brake opening time "T_5" in the "Stop" menu and
increase if necessary
Translation of the original operating instructions
ZETADYN 4C
Error diagnosis
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
141/204
1
4
Error
diagnosis
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...