Parameter
Description
Value range
Factory set-
ting
CONFIG
Con
fi
guration of the digital inputs according to the used control
system and type of communication
00:Free:
Outputs are freely con
fi
gurable
01:ZA_IO:
Ziehl-Abegg standard control
02:ZA_CAN:
Ziehl-Abegg CAN
03:BP_IO:
Böhnke+Partner standard control
04:BP_DCP1:
Böhnke & Partner DCP1
05:BP_DCP2:
Böhnke & Partner DCP2
06:BP_DCP3:
Böhnke & Partner DCP3
07:BP_DCP4:
Böhnke & Partner DCP4
08:KN_IO:
Kollmorgen standard control
09:KN_DCP3:
Kollmorgen DCP3
10:KN_DCP4:
Kollmorgen DCP4
11:NL_IO:
New Lift standard control
12:NL_DCP3:
New Lift DCP3
13:SS_IO:
Schneider Steuerungen standard control
14:SS_DCP3:
Schneider Steuerungen DCP3
15:ZA_BIN:
Ziehl-Abegg standard control with binary speed
presetting
16:WL_IO:
Weber Lifttechnik standard control
17:WL_DCP1
: Weber Lifttechnik DCP1
18:WL_DCP2
Weber Lifttechnik DCP2
19:WL_DCP3
Weber Lifttechnik DCP3
20:WL_DCP4
Weber Lifttechnik DCP4
21:ST_IO
Strack Lift Automation standard control
22:ST_DCP3
Strack Lift Automation DCP3
23:ST_DCP4
Strack Lift Automation DCP4
24:CSILVA:
Carlos Silva standard control
25:S+S:
Sohn standard control
26:KW_DCP3:
KW Aufzugstechnik DCP3
27: MAS_BIN:
Masora standard control
28: BU_SATU:
Hydraulic elevator aggregate with Bucher-Ag-
gregat type Saturn ALPHA
29: BU_ORIO:
Hydraulic elevator aggregate with Bucher-Aggre-
gat type Orion ALPHA
30: KS_IO:
Georg K
ü
hn Control systems standard control
31: KL_IO:
Kleemann standard control
32: S_SMART:
Schindler Smart standard control
00:Free
01:ZA_IO
02:ZA_CAN
03:BP_IO
04:BP_DCP1
05:BP_DCP2
06:BP_DCP3
07:BP_DCP4
08:KN_IO
09:KN_DCP3
10:KN_DCP4
11:NL_IO
12:NL_DCP3
13:SS_IO
14:SS_DCP3
15:ZA_BIN
16:WL_IO
17:WL_DCP1
18:WL_DCP2
19:WL_DCP3
20:WL_DCP4
21:ST_IO
22:ST_DCP3
23:ST_DCP4
24:CSILVA
25:S+S
26:KW_DCP3
27:MAS_BIN
28:Bucher_SATU
29:Bucher_ORIO
30:KS_IO
31:KL_IO
32:S_SMART
01:ZA_IO
MO_DR
Changing the rotating direction of the motor
It must be observed the with triggering the input RV1 the cabin
drives upwards
left:
Rotary direction left
right:
Rotary direction right
left
right
left
BR
Motor brake monitoring
Input of number and function of the brake monitoring contacts
used
OFF:
no brake monitoring connected
1*NC:
1x normally closed contact (Contact closed when brake
currentless)
2*NC:
2 x normally closed contact (Contact closed when brake
currentless)
3*NC:
3 x normally closed contact (Contact closed when brake
currentless)
1*NO:
1 x normally open (contact is open when brake current-
less)
2*NO:
2 x normally open contact (contact is open when brake
currentless)
3*NO:
3 x normally open (contact is open when brake current-
less)
Off
1*NC
2*NC
3*NC
1*NO
2*NO
3*NO
accordingly to
motor type
Translation of the original operating instructions
ZETADYN 4C
Parameter list
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
72/204
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...