MotDatFW- - - - - - - - -
05
I: 11.0A n: 1560rp
cos:0.89 f: 53.4Hz
I0: 3.5A TR: 316ms
Page 05: MotDatFW
Display of the calculated motor data with
fi
eld weakening operation:
Line 2:
Rated current
Nominal speed
Line 3:
cos phi
Rated frequency
Line 4:
Magnetization current
Rotor time constant
MotDatNom - - - - - - - -
05
I: 11.0A n: 1450rp
cos:0.88 f: 50.0Hz
I0: 3.8A TR: 316ms
Seite 05: MotDatNom
By pressing the button, the original motor date wiill be displayed
RegLimits - - - - - - - -
06
SP IQ ID PS U
LIM:..
·
. .. .. .
PEK:
Page 06: RegLimits
Online display of whether a control loop has reached the limit
Line 2:
SP: Speed controller
IQ: Current controller (torque creation current)
ID: Current controller (
fl
ux creation current)
PS: Position controller
U: Voltage limit of the frequency inverter
Line 3:
Alarm bell left: minimum limit reached
Alarm bell right: maximum limit reached
No alarm bell should appear during a faultless, normal trip.
Brake Chopper - - - - -
07
Internal 1.4kHz BC
·
U_DC:_ _ _ _ _ _ 565V
Ampl:_ _ _ _ _ _ 0%
Page 07: Brake-Chopper
Online-display
Line 2:
Internal PWM frequency (only for brake resistor)
Condition of function and temperature monitoring on the input terminal BC (larger point = OK)
Line 3:
DC-link voltage as bar chart display
DC-link voltage
Line 4 (only with Brake resistor):
Modulation of Brake resistor as bar chart display
Modulation of Brake resistor in %
The DC-link voltage displayed in standstill must have the value
“
Mains connection voltage x
1,41".
A large point must constantly be displayed behind the function and condition monitor.
Pressing the button
Display will be frozen
Display of the loaf of the brake resistor (average value over 120s)
Translation of the original operating instructions
ZETADYN 4C
Parameter list
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
97/204
1
1
Parameter
list
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...