The control system starts the evacuation trip by activating:
•
Controller enable
•
Direction preset (in the direction of the pulling load)
•
Speed default
13.2.1
Evacuation through UPS with optimum power
Information - Characteristics of evacuation with optimum UPS power
•
Load-independent starts
•
Load-independent stopping
•
Flush stopping
•
With corresponding sizing of the UPS, a trip in the motoric direction is also feasible.
Calculation of the UPS
The required UPS performance consists of the following:
Power consumption electronics ZETADYN 4
+ Control systempower consumption
+ Electromechanical brakes power consumption
+ Other consumers (car light,
…
) power consumption
+ Motor power consumption for UPS operation with suf
fi
cient power (ask
motor manufacturer)
=
Real power UPS [W]
Information
The shaft ef
fi
ciency has a decisive in
fl
uence on the required power of the UPS performance.
13.2.2
Evacuation through UPS with minimum power
Information - Evacuation through UPS with minimum power
•
Load-dependent starting, cannot be optimized
•
Evacuation only possible in the direction of the pulling load
•
Positioning is carried out load dependent; that means step formation could occur.
Calculation of the UPS
The required UPS performance consists of the following:
Power consumption electronics ZETADYN 4
+ Control systempower consumption
+ Electromechanical brakes power consumption
+ Other consumers (car light,
…
) power consumption
+ Motor power consumption for UPS operation with reduced power (ask
motor manufacturer)
=
Real power UPS [W]
Information
The shaft ef
fi
ciency has a decisive in
fl
uence on the required power of the UPS performance.
Translation of the original operating instructions
ZETADYN 4C
Emergency evacuation
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
122/204
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...