Work on electric components may only be carried out by trained electricians or by persons instructed
in electricity under the supervision of an electrician in accordance with electrical engineering regula-
tions.
A second person must always be present when working on energized parts or lines who disconnects
in case of emergency.
Inspect electrical equipment periodically: retighten loose connections
–
immediately replace damaged
lines and cables.
Always keep switch cabinets and all electrical supply facilities locked. Access is only allowed for
authorized persons using a key or special tool.
Never clean electrical equipment with water or similar liquids.
5.1
EMC-compatible installation
When correctly installed (see below), the frequency inverter corresponds to the following standards:
•
EN 12015:2004 Electromagnetic compatibility
–
Product family standard for lifts, escalators and
moving walks
–
Emission
•
EN 12016:2004 + A1:2008 Electromagnetic compatibility
–
Product family standard for lifts, escala-
tors and moving walks
–
Immunity
The following points must be observed if the above mentioned standards are to be adhered to:
•
Use only shielded cables for motor and brake chopper or brake resistor connections
•
Max. motor line length is 25 m
•
Wind unshielded cables of brake resistor type BR11-A around the toroidal core provided (see
fi
gure)
•
If you must interrupt the shielding on a cable (e.g., to install a motor contactor), the shielding must
be subsequently continued with the lowest possible HF impedance.
•
Use only shielded control cables
•
The shielding of power cables (motor cable, Brake-Chopper cable) must be connected to ground
on both sides
•
The shielding of control cables (inputs and outputs, rotary encoder cable, etc.) must be connected
to earth potential on the inverter side
•
Use shielded lines in the switching cabinet also
•
Do not twist shielding for connections; use a suitable shield connection system
•
Run the control cables and the encoder cables separate from the power cables
•
Provide connected inductances (brakes, motor contactors) with suppressors
•
Feed the power supply of the motor contactors through the mains
fi
lter of the lift control
Information
Please contact the manufacturer for information on adhering to the limit value class B in accordance
with EN 55011.
Toroidal core BR11-A
Translation of the original operating instructions
ZETADYN 4C
Electrical installation
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
16/204
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...