Error no.
Error text
Error cause
M S
117
127
MP: No ID
The print module ID no. was not detected:
Module Print is not present or its ID EEPROM does not reply
●
121
CUSH: ID-Error
Internal shunt module was detected but there are problems with the shunt
module's informational content
●
140
MP:Unknown IGBT
A unknown IGBT-module was recognized
141
MP: Temp.Sens?
The external temperature sensor for the Modul Print is not recognized
●
150
HW-Con
fl
ict !
Shuntmodul, Power Print and Modul Prind do not match
160
ADC adj.:outside tol.
Error:
2The deviation between the
fi
rst measured value and the second meas-
ured value during the zero point comparison of the motor current measurement
is greater than 2 %.
●
174
CUMT:Not detect
Option module for the temperature monitoring of the motor is nit recognized:
Check the con
fi
guration for rhe temperature monitoring in the "Monitoring"
menu
●
180
UF CTRL=DCP2/4
Error:
DCP2 or DCP4 is con
fi
gured as the actuation type. This is not possible
during operation without a rotary encoder
Remedy:
Enter DCP1 or DCP3 for the communication
●
14.5.5
Error 2xx
•
Con
fi
guration error
Error no.
Error text
Error cause
M S
200
Stop input
Error:
A parameter is open while apply a correct travel command (RF + RVx +
Vx)
Remedy:
End parameter inputs
●
201
Motor name plate
Error:
a parameter in the "Motor name plate" menu has not been assigned
Remedy:
Check the parameter in the "Motor name plate" menu,
202
MOT_TYP = ?
Error:
No motor type was selected in the "Motor name plate" menu
Remedy:
Enter in the "Motor name plate"menu
●
203
n* = 0?
Error:
No speed was entered in the "Installation" menu
Remedy:
Enter the speed at V* in the "Installation" menu directly or have it
calculated based on the installation data
●
204
n* > 3*n
Error:
n* was incorrectly calculated due to incorrect installation data (n* >3xn)
Remedy:
Check the installation data for correct entry
●
205
Input duplicated
Error:
two digital inputs are assigned with the same function
Remedy:
Change the function allocation of the digital inputs
●
207
Input PFU_BR miss.
Fault:
When using a feedback unit in connection with a brake resistor the
temperature monitor of the brake resistor is not programmed
Remedy:
Parameterise digital input (preferably X_BR4) in the "Control" menu
to the "PFU_BR" function
●
208
DELAY active
Error:
Emergency stop was done by deactivating of the input with the function
"/DELAY"
At travel start, the input with the function "/DELAY" is not active
Remedy:
Check the triggering of the input with the function "/DELAY"
210
Wrong ENC_TYP
Error:
Rotary encoder type and motor type are not compatible
Remedy:
Enter the correct rotary encoder type in the "Encoder & BC" menu
●
●
211
No binary encoder
Error:
Binary resolution not con
fi
gured for rotary encoder type TTL sinus or
EnDat/SSI
Remedy:
Enter a binary resolution (e.g. 512, 1024 or 2048)
213
ZR_EN /ZR_RDY miss-
ing
Error:
"ZR_RDY" or "ZR_EN" was not con
fi
gured
Remedy:
Set digital input to "ZR_RDY" or set digital output to "ZR_EN"
220
Error: SM data
Error:
While operating synchronous motors, the values for the rated speed (n)
and the rated frequency (f) do not match in the "Motor name plate" menu
Remedy:
Enter the correct data for rated speed and rated frequency in the
"Motor name plate" menu
●
●
Translation of the original operating instructions
ZETADYN 4C
Error diagnosis
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
133/204
1
4
Error
diagnosis
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...