11.14
Parameter set 2 menu
A second parameter set can be stored in the frequency inverter. This can be used for:
•
Emergency evacuation
•
Normal travel with changed parameter values
•
Parameter back-up
Parameter
Description
Value range
Factory set-
ting
F_PAR2
Function allocation of parameter set 2
Locked:
2.nd parameter set is blocked
2.ndParameter set:
Activates the 2.nd parameter set
EVAC 3:
Emergency evacuation with evacuation module EVAC
3
EVA. 3*AC:
Emergency evacuation through three-phase current
emergency-generator
EVA. 1*AC:
Emergency evacuation through UPS
UPS:
Emergency evacuation through UPS (with decreased
power)
Locked
2nd parameter set
EVAC 3
EVA. 3*AC
EVA. 1*AC
UPS
Locked
U_ACCU
Accu nominal voltage
Con
fi
guring the rated voltage of the rechargeable battery during
evacuation with evacuation unit EVAC 3 ("f_PARA2=EVAC 3B",
see "Emergency evacuation" chapter)
60 ... 565 V
120
P_UPS
Max. Load UPS
Con
fi
guring the available power of the UPS during evacuation
with UPS ("f_PARA2=UPS", see "Emergency evacuation" chap-
ter)
0.0 ... 70.0 kW
1.0
RS_UPS
Stator resistor
Enter the resistor of the stator of themotor with "f_PARA2=UPS"
0.0 ... 9.99 Ohm
1.00
STOP
Stop function to improve the positioning accuracy in the evacua-
tion mode "f_PARA2=UPS"
ON:
- Brake is closed when the switch point for V_1 is closed.
- Brake is closed when the residual path con
fi
gured in S_STOP
has been reached (only for DCP02/04
Off:
Stop function deactivated
On
Off
Off
Copy
Copy parameter set
OFF:
Function deactivated
PARA1->2:
copies the data from 1st parameter set into the 2nd
parameter set
Off
Para 1->2
Off
11.15
Statistic menu
All statistical data can be called up in the
Statistic
menu. The data remain saved even after the
ZETADYN 4 has been switched off. Reading out the error list and deleting the error memory are
described in the "Error diagnosis" chapter.
Information
Not all parameters are visible when the
Statistic
menu is opened in the basic level.
Parameter
Description
Value range
Factory
setting
visible in
the basic
level
ST_LST
Error list
Cannot be set
-
X
ST_H
Operating hours
Cannot be set
-
X
ST_DRV
Number of trips
Cannot be set
-
X
ST_HDRV
Number of travel hours
Cannot be set
-
X
ST_UC
Usage category in accordance with VDI 4707
Cannot be set
-
X
ST_RES
Number of mains interruptions
Cannot be set
-
X
Translation of the original operating instructions
ZETADYN 4C
Parameter list
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
88/204
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...