X-MON
+24V_
CO
CO1
CO2
K1
K2
(1)
(2)
(3)
Connection internal contactor monitoring
–
series circuit
1
Parameter "Monitoring/CO=CO1"
()
terminal designation of connector
X-MON
+24V_
CO
CO1
CO2
K1
K2
(1)
(2)
(3)
Connection internal contactor monitoring
–
separate
1
Parameter "Monitoring/CO=CO1&CO2"
()
terminal designation of connector
CAUTION!
Caution!
The internal 24 V power supply is provided solely for the contactor monitoring. Switching consumer
load with this voltage is prohibited!
5.22
Brakes
5.22.1
Brake release monitoring (X-BR)
Information
The brake release monitoring serves as monitoring for redundancy and the operation status of the
brakes.
It is recommended to connect the brake air monitor to the ZETADYN 4C for optimum starting and
stopping.
The monitoring conforms chapter 9.10 of EN81-1:2010 for brakes as protection for the upside traveling
elevator car against overspeed.
When the lock function is activated, the brake release monitoring ful
fi
ls the requirements for self-
monitoring according to chapter 9.11.3 EN81-1:2010 for brake elements for protection against unin-
tended movement of the cabin.
Monitoring voltage
+24 VDC / 8 mA
Contact type
Normally open contact (NO) or nor-
mally closed contact (NC)
Number of inputs
4
Clamping range
max. 1,5 mm
²
Current consumption at 24 V
typ. 8 mA
The contactor monitoring can be activated/deactivated in the menu
Monitoring
.
Monitors
|
-
"
BR
1*NC
|
-
"
3*NC
Brake monitor
The lock function of the ZETADYN is engaged by activating the
“
LOCKBR=On
”
parameter in the
menu
Monitoring
.
Monitoring
|
-
"
LOCKBR
Off
|
-
"
On
Lock inverter
Activation of the parameter ensures that the ZETADYN locks on detection of a faulty brake circuit.
The ZETADYN lock can only be released by setting the
“
Monitors / UNLOCK = On
”
parameter.
Translation of the original operating instructions
ZETADYN 4C
Electrical installation
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
43/204
5
Electrical
instal-
lation
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...