Adjust encoder mechani-
cally?
No
Yes
Adjustment by entering the offset value:
The encoder is not moved mechanically, the off-
set value is retained and is corrected by entering
the encoder offset value in the controller unit.
The offset value must be available when chang-
ing devices!
If the value is not available, a new encoder ad-
justment must be made!
Mechanical adjustment of the encoder:
Adjust the encoder as exactly as possible to the
value
0
°
by turning and tighten the locking screw
carefully, correct the encoder position if neces-
sary.
At the end of the adjustment procedure the en-
coder must be tightened and value close to
0
.
At deviations less than
±
2.00
°
the adjustment is
considered correct. A
deviation of max.
±
1
°
is recommended.
End the adjustment procedure by switching off
the inspection run.
End the adjustment procedure by switching off
the inspection run.
Please check and
if necessary set
ENC_OFF=249.32
°
[OK]
Mechanical SSI
adjustment is quite
correct!
[OK]
The encoder offset must be corrected to the
speci
fi
ed value!
The value must be noted.
Encoder Calibration
|
-
"
ENC_OFF 249.32
DEG
|
-
"
249.32
Encoder Offset
Translation of the original operating instructions
ZETADYN 4C
Special functions
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
155/204
1
6
Special
functions
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...