Scroll through fault list:
the fault list can be scrolled through using the two arrow keys.
Scroll up (reduce fault serial number)
Scroll down (increase fault serial number)
Determine time of fault
When i key is pressed, the difference from the current number of
travels and operting time is displayed
"
BC:Alarm/fault
3
E912 S422 -2.4h
-0000189 12C
"
01 RV1 0.00m +12A
In CANopen lift and DCP operation, the time at which an error occurs is saved in the error list and
displayed.
? B R : F a h r t - F e h l e r ?
E 5 8 3 S 4 3 0 1 0 : 3 0
0 0 0 0 0 7 6 x x x 2 8 C
?
0 0
R V 1 5 . 9 1 m + 1 2 A
1
1
Time at which the error occurred
14.4
Delete error memory
The fault memory is wiped by means of an entry in the
Statistic/ST_CLR=ON
.
The following parameters are reset:
•
ST_LST (Error list)
•
ST_RES (Number of interruptions in the mains supply)
•
ST_SRF (Number of trip interruptions due to an interruption in the control enabling)
•
ST_SCO (Number of trip interruptions due to an interruption in the contactor monitor)
14.5
Error list
All error messages are stored in the
Statistic / ST_LST
menu (see "Error diagnosis / error memory"
chapter)
14.5.1
Masc-Funktion
You can deactivate individual monitoring functions by inputting an item in the error mask (see
"Parameter list/Monitoring" menu chapter). To do this, enter the corresponding error number into error
masks 1-5.
The maskable errors are marked in the error list with a
point
in thecolum n
M
.
CAUTION!
Caution!
The mask function may only be used for troubleshooting and error diagnostics. The corre-
sponding error cause must be eliminated in order to ensure continuous service of the fre-
quency inverter!
Sequential errors can occur if errors are masked.
The masking deactivates important monitoring functions. This may result in dangerous operat-
ing states or damage to the frequency inverter.
Translation of the original operating instructions
ZETADYN 4C
Error diagnosis
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
131/204
1
4
Error
diagnosis
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...