Start-up and acceleration
RF
Controller enable
V_1
Positioning speed
V_3
Travel Speed
RV1 / RV2
Direction default
RB
Controller ready
MB_Brake
Mechanical brake
12.3
Optimizing start up behavior
Optimizing the start up behavior is only necessary if there is a negative in
fl
uence on the travel comfort
(e.g. through start up jerks)
Information
•
Proper installation condition (rail guides, car suspension, transmission oil
fi
lling, etc.)
•
The car must be empty and the counterweight completely loaded. Start-up for all loading conditions
can only be optimally adjusted in under these conditions
•
The speed control parameters must be correctly set in the
Controller
menu (see "Commissioning /
Setting the speed control" chapter)
Start-up time sequence
T_0
Time until motor contactors have been opened
T_1
Time until magnetizing
fl
ux has been built up (only with asynchronous motors)
T_2
Time until brake has been opened
T_3
Time in which the motor is controlled to speed 0 or accelerated to V_T3
RF
Controller enable
Vx
Travel speed V_3
RVx
Travel direction
ST
Controller failure
MB_Brake
Mechanical brake
RB
Controller ready
The various times can be set in the
Start
menu
Translation of the original operating instructions
ZETADYN 4C
Travel options
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
105/204
1
2
Travel
options
Содержание ZETADYN 4C
Страница 192: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 192 204 ...
Страница 194: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 194 204 ...
Страница 196: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 196 204 ...
Страница 198: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 198 204 ...
Страница 200: ...Translation of the original operating instructions ZETADYN 4C Enclosure R TBA12_01 GB 1415 Part No 00163371 GB 200 204 ...