YX3000 Senseless Vector Type Inverter Manual
- 87 -
6.3 Start/Brake Function Parameter (P2 Group)
P2.00
Start running mode
Range: 0, 1, 2
0
0
:
The inverter starts from start freq.(P2.01) and keeps running at start freq. for duration
defined as start freq. running duration (P2.02).
1
:
The inverter brakes first by DC brake current (P2.03) and brake time (P2.04),and then
starts from start frequency
2
:
The inverter restarts again after speed tracking, which is available for power restored
after momentary power failure and restart after fault reset.
Fig.6-9 Speed tracking restart
Fig.6-10 Start freq. and running duration
Note:
(1) Start running mode 0: It is suggested to use mode 0 in general applications and
when to drive synchronous motor.
(2) Start running mode 1: It is suitable to small inertia loads which have FWD or REV
running when there is no motor driven. But not suitable to big inertia loads.
(3) Start running mode 2: It is suitable to restart after momentary power failure and
restart during motor free stopping.
P2.01
Start freq
Range: 0.20
~
10.00Hz
0.50 Hz
P2.02
Start freq. running duration
Range: 0.0
~
30.0S
0.0S
Start freq. is the initial frequency when inverter starts shown as Fig.6-10 Fs. Start freq.
running duration is the duration time for inverter keeping running at start frequency shown as
Output Freq
On
On
Off
speed
power
time
t
1
start freq running duration
F
s
F
max
Freq Hz
Start
freq
Содержание YX2000
Страница 18: ...YX3000 Senseless Vector Type Inverter Manual 17 2 4 Dimensions W H W1 H1 D a Inverters below 7 5KW...
Страница 19: ...YX3000 Senseless Vector Type Inverter Manual 18 W W1 H H1 D b Inverters from 11KW to 90 KW...
Страница 20: ...YX3000 Senseless Vector Type Inverter Manual 19 W1 H2 H1 D W H c Inverters from 110KW to 250 KW...
Страница 21: ...YX3000 Senseless Vector Type Inverter Manual 20 W H D d Inverters from 285KW to 315KW...
Страница 22: ...YX3000 Senseless Vector Type Inverter Manual 21 W H D e Inverters from 350KW to 630KW...