YX3000 Senseless Vector Type Inverter Manual
- 141 -
Current waveform abnormal
due to output missing phase,
etc.
Check wiring
Auxiliary power damaged, or
driving voltage under voltage
Contact supplier
Control board abnormity
Contact supplier
E-13
Peripheral
fault
Close external fault terminals Check the reason
E-14
Current
detecting
circuit fault
Loose
wiring
or
terminal
connections
Check and re-wiring
Auxiliary
power
source
damaged
Contact supplier
Hall component damaged
Contact supplier
Abnormal amplifier circuit
Contact supplier
E-15
RS232/485
Communication
fault
Wrong baud rate setting
Set baud rate properly
Serial port communication fault Press
Key to reset or
contact supplier
Improper fault alarm parameter
setting
Revise function code P3.09~P3.12
Upper computer doesn’t work
Check
upper
computer
and
connecting cable
E-16
System
interference
Serious interference
Press
key to reset or install
input power source filter
DSP read/write error
Reset or contact supplier
E-17
EP
2P
PROM
error
Read/write error of control
parameter
press
key to reset or install
input power source filter
STOP
RESET
STOP
RESET
STOP
RESET
Содержание YX2000
Страница 18: ...YX3000 Senseless Vector Type Inverter Manual 17 2 4 Dimensions W H W1 H1 D a Inverters below 7 5KW...
Страница 19: ...YX3000 Senseless Vector Type Inverter Manual 18 W W1 H H1 D b Inverters from 11KW to 90 KW...
Страница 20: ...YX3000 Senseless Vector Type Inverter Manual 19 W1 H2 H1 D W H c Inverters from 110KW to 250 KW...
Страница 21: ...YX3000 Senseless Vector Type Inverter Manual 20 W H D d Inverters from 285KW to 315KW...
Страница 22: ...YX3000 Senseless Vector Type Inverter Manual 21 W H D e Inverters from 350KW to 630KW...