![Yuanxin Electric YX2000 Скачать руководство пользователя страница 148](http://html1.mh-extra.com/html/yuanxin-electric/yx2000/yx2000_user-manual_3653394148.webp)
YX3000 Senseless Vector Type Inverter Manual
- 147 -
doesn’t answer.
3)
The address, baud rate and data format of the inverter can be setup by using the
keyboard or the serial communication.
4)
message of error is reported by slave, in the recent response frame against host
polling
9.2.3 Communication Interface
The communication is using RS485 interface, with asynchronous serial and half-duplex
transmission. The default communication protocol is in ASCII mode.
The default data format: 1 start bit, 7 data bits, 2 stop bits.
The default rate is 9600bps. Communication parameter settings reference P3.09 ~ P3.12
function code.
9.3 ASCII protocol
Character structure:
10 characters box
(
For ASCII
)
(1-7-2 format, no parity)
Start
bit
1
2
3
4
5
6
7
Stop
bit
Stop
bit
(1-7-1 format, odd parity)
Start
bit
1
2
3
4
5
6
7
Parity
bit
Stop
bit
(1-7-1 format, even parity)
Start
bit
1
2
3
4
5
6
7
Parity
bit
Stop
bit
11 characters box
(
For RTU
)
(1-8-2 format, no parity)
Содержание YX2000
Страница 18: ...YX3000 Senseless Vector Type Inverter Manual 17 2 4 Dimensions W H W1 H1 D a Inverters below 7 5KW...
Страница 19: ...YX3000 Senseless Vector Type Inverter Manual 18 W W1 H H1 D b Inverters from 11KW to 90 KW...
Страница 20: ...YX3000 Senseless Vector Type Inverter Manual 19 W1 H2 H1 D W H c Inverters from 110KW to 250 KW...
Страница 21: ...YX3000 Senseless Vector Type Inverter Manual 20 W H D d Inverters from 285KW to 315KW...
Страница 22: ...YX3000 Senseless Vector Type Inverter Manual 21 W H D e Inverters from 350KW to 630KW...