8 customized V/Fcurve
P0.22=4, Customized V/F curve shown as Fig. 6-8.
User can define V/F curve through revising (V1,F1),(V2,F2),(V3,F3) so as to meet special
load requirements. Torque boost is available for customized curve.
Vb
=
Torque boost
(
P0.09
)
× V1
6.2 Frequency Setting Function Parameter (PP11 Group)
P1.00
Analog filter time constant
Range: 0.01
~
30.00s
0.20s
When adopts frequency external analog channel setting mode, time constant is inverter
filtering sampling value time. When long distance wiring or serious interference cause setting
frequency unstable, increase this time constant to avoid the disoperation . The longer filtering
time, anti-interference ability will be stronger. But the response will be slower. The shorter
filtering time it has, the quicker response, but weaker anti-interference ability.
P1.01
VI channel gains
Range: 0.01
~
9.99
1.00
P1.02
VI min.given
Range: 0.00
~
P1.04
0.00V
P1.03
Corresponding freq to VI
min.given
Range: 0.00
~
upper limit freq
0.00Hz
P1.04
VI max.given
Range: P1.04
~
10.00V
10.00V
Freq. Hz
Volt.
%
100
%
V
3
V
F1
F2
F3
Содержание YX2000
Страница 18: ...YX3000 Senseless Vector Type Inverter Manual 17 2 4 Dimensions W H W1 H1 D a Inverters below 7 5KW...
Страница 19: ...YX3000 Senseless Vector Type Inverter Manual 18 W W1 H H1 D b Inverters from 11KW to 90 KW...
Страница 20: ...YX3000 Senseless Vector Type Inverter Manual 19 W1 H2 H1 D W H c Inverters from 110KW to 250 KW...
Страница 21: ...YX3000 Senseless Vector Type Inverter Manual 20 W H D d Inverters from 285KW to 315KW...
Страница 22: ...YX3000 Senseless Vector Type Inverter Manual 21 W H D e Inverters from 350KW to 630KW...