YX3000 Senseless Vector Type Inverter Manual
- 36 -
GND
+10Vcommon
port
Grounding of analog signal and+10V
power source
Terminal COM and GND
are
Isolated inside
COM
+24Vcommon
port
Digital signal input, output common
port
3.6.3 Analog Input/Output Terminal Wiring
(1) Analog voltage signal input through VI terminal as follow wiring
:
(2) Analog signal input through CI terminal, jumper selection for input voltage (0~10V) or input
current (4~20mA) as follow wiring
Fig. 3-8 CI terminal wiring
+
―
10V
VI
GND
PE
YX3000
Shielded cable
proximal grounding
0~+10V
Fig. 3-7 VI terminal wiring
JP3
+
―
10V
CI
GN
PE
CI current
I
CI
V
CI
YX3000
Shielded cable
proximal
0~+10V
OR
JP3
I
C
I
V