7-15
IM CW140-E
Common Functions of All Modes
7
●
Sampling in Harmonics Mode
(for Fundamental Wave Frequency of 45 to 65 Hz)
50 Hz
20 msec
Two periods
256
256
512 samples
Calculation time
Frequency
measurement
input
Zero crossing
signal
V1
(Sine wave)
The sampling period synchronizes with the zero crossing signal of the
frequency measurement input a PLL. Two periods' worth of samples (i.e., 512
samples) are used to perform the calculation of harmonic parameters.
TIP
In the examples shown above, the waves are sine waves (50 Hz) generated by using the voltage input
V1.
7.4 Sampling Frequencies and Integration Periods