IM CW140-E
App 2-12
Command
Description
:INTEgrate:STORe:ITEM?
Queries all the settings relating to data items to be saved
:INTEgrate:STORe:ITEM:IGR
Sets/queries whether current-group data output is set to ON or
OFF
:INTEgrate:STORe:ITEM:EVENt
Sets/queries whether event-group data output is set to ON or
OFF
:INTEgrate:STORe:ITEM:PGR
Sets/queries whether power-group data output is set to ON or
OFF
:INTEgrate:STORe:ITEM:VGR
Sets/queries whether voltage-group data output is set to ON or
OFF
:INTEgrate:STORe:ITEM:WHGR
Sets/queries whether electric-energy-group data output is set to
ON or OFF
:INTEgrate:STORe:MEMOry
Sets/queries whether data output to internal memory is set to ON
or OFF
:INTEgrate:WH?
Queries all the settings relating to decimal point and unit of
electric energy.
:INTEgrate:WH:DIGIt
Set/queries position of decimal point of electric energy.
:INTEgrate:WH:UNIT
Set/queries unit of measurement of electric energy.
INSTant Group
:INSTant?
Queries all the settings relating to instantaneous value
measurement
:INSTant:AOUT?
Queries all the settings relating to D/A output
:INSTant:AOUT:CHANnel<x>
Sets/queries D/A-output data items
:INSTant:DISPlay?
Queries all the settings relating to measurement screen
:INSTant:DISPlay:EXPAnd<x>
Sets/queries the data items for expanded view
:INSTant:DISPlay:LOAD
Sets/queries the load whose data is measured and viewed
:INSTant:DISPlay:MODE
Sets/queries the mode of measurement screen
:INSTant:STATe?
Queries the measurement status
:INSTant:STORe?
Queries all the settings relating to output destination and data
items to be saved
:INSTant:STORe:STATe
Sets/queries whether logging is set to ON or OFF
:INSTant:STORe:FD
Sets/queries whether data output to floppy disks is set to ON or
OFF
:INSTant:STORe:FILEname
Sets/queries the name of a file to be saved
:INSTant:STORe:INTErval
Sets/queries the time interval for logging output
:INSTant:STORe:ITEM?
Queries all the settings relating to data items to be saved
:INSTant:STORe:ITEM:IGR
Sets/queries whether current-group data output is set to ON or
OFF
:INSTant:STORe:ITEM:EVENt
Sets/queries whether event-group data output is set to ON or
OFF
:INSTant:STORe:ITEM:PGR
Sets/queries whether power-group data output is set to ON or
OFF
:INSTant:STORe:ITEM:VGR
Sets/queries whether voltage-group data output is set to ON or
OFF
:INSTant:STORe:MEMOry
Sets/queries whether data output to internal memory is set to ON
or OFF
:INSTant:STORe:STARt?
Queries all the settings relating to the start of logging
Appendix 2. Communication Commands
Содержание CW140
Страница 1: ...User s Manual CW140 CLAMP ON POWER METER IM CW140 E IM CW140 E 3rd Edition July 2001 YK ...
Страница 2: ......
Страница 14: ......
Страница 72: ......
Страница 102: ......
Страница 138: ......
Страница 152: ......
Страница 160: ......
Страница 200: ......
Страница 256: ......
Страница 274: ......
Страница 276: ......
Страница 286: ......
Страница 289: ......