IM CW140-E
App 2-14
Command
Description
:MEASure:HARMonics:ITEM;F
Sets/queries whether Harmonics Measure mode communication-
output frequency data is set to ON or OFF
:MEASure:HARMonics:ITEM:ORDEr
Sets/queries the order of Harmonics Measure mode
communication-output data
:MEASure:HARMonics:ITEM:PF
Sets/queries whether Harmonics Measure mode communication-
output power factor data is set to ON or OFF
:MEASure:HARMonics:ITEM:V<x>?
Queries all the settings relating to Harmonics Measure mode
communication-output voltage data items
:MEASure:HARMonics:ITEM:V<x>:CONT<x>
Sets/queries whether Harmonics Measure mode communication-
output harmonic voltage content data is set to ON or OFF
:MEASure:HARMonics:ITEM:V<x>:CSA
Sets/queries whether Harmonics Measure mode communication-
output voltage THD/CSA data is set to ON or OFF
:MEASure:HARMonics:ITEM:V<x>:IEEE
Sets/queries whether Harmonics Measure mode communication-
output voltage THD/IEEE data is set to ON or OFF
:MEASure:HARMonics:ITEM:V<x>:PA<x>
Sets/queries whether Harmonics Measure mode communication-
output voltage phase angle data is set to ON or OFF
:MEASure:HARMonics:ITEM:V<x>:RMS<x>
Sets/queries whether Harmonics Measure mode communication-
output rms voltage data is set to ON or OFF
:MEASure:HARMonics:ITEM:V<x>:TOTAl
Sets/queries whether Harmonics Measure mode communication-
output total rms voltage data is set to ON or OFF
:MEASure:HARMonics:ITEM:P<x>
Sets/queries whether Harmonics Measure mode communication-
output power data is set to ON or OFF
:MEASure:HARMonics:ITEM:PCONt<x>
Sets/queries whether Harmonics Measure mode communication-
output harmonic power data is set to ON or OFF
:MEASure:HARMonics:ITEM:PPA<x>
Sets/queries whether Harmonics Measure mode communication-
output power phase angle data is set to ON or OFF
:MEASure:HARMonics:ITEM:PTOTal
Sets/queries whether Harmonics Measure mode communication-
output total power data is set to ON or OFF
:MEASure:HARMonics:VALUe?
Queries the measurement data item set with a command that
follows the :MEASure:HARMonics:ITEM query
:MEASure:INTEgrate?
Queries all the settings relating to Electric Energy Measure mode
communication-output data
:MEASure:INTEgrate:ITEM?
Queries all the settings relating to Electric Energy Measure mode
communication-output data items
:MEASure:INTEgrate:ITEM<Electric Energy Measure mode data item>
Sets/queries whether Electric Energy Measure mode
communication-output data items are set to ON or OFF
:MEASure:INTEgrate:ITEM:ALL
Sets all effective Electric Energy Measure mode communication-
output data to ON
:MEASure:INTEgrate:ITEM:CLEAr
Sets all effective Electric Energy Measure mode communication-
output data to OFF
:MEASure:INTEgrate:ITEM:VALUe?
Queries the measurement data item set with a command that
follows the :MEASure:INTEgrate:ITEM query
:MEASure:INSTant?
Queries all the settings relating to Instant Measure mode
communication-output data
:MEASure:INSTant:ITEM?
Queries all the settings relating to Instant Measure mode
communication-output data items
Appendix 2. Communication Commands
Содержание CW140
Страница 1: ...User s Manual CW140 CLAMP ON POWER METER IM CW140 E IM CW140 E 3rd Edition July 2001 YK ...
Страница 2: ......
Страница 14: ......
Страница 72: ......
Страница 102: ......
Страница 138: ......
Страница 152: ......
Страница 160: ......
Страница 200: ......
Страница 256: ......
Страница 274: ......
Страница 276: ......
Страница 286: ......
Страница 289: ......