19-15
IM CW140-E
Specifications
19
19.2 Specifications of Current Clamps
(1) Specifications of Clamp-on Probe (96030, 96031)
Model No.
960 30
(Clamp A)
200A
960 31
(Clamp C)
500A
Measurement range
0-200 Arms AC (300 Apk)
0-500 Arms AC (750 Apk)
Output voltage
0-0.5 Vrms AC (2.5mV/A)
0-0.5 Vrms AC (1mV/A)
Accuracy
Amplitude
±
1.5%rdg
±
0.4 mV (20 Hz to 45 Hz)
±
1.5% rdg
±
0.4 mV (20 Hz to 45 Hz)
±
0.5%rdg
±
0.1 mV (45 Hz to 66 Hz)
±
0.5% rdg
±
0.1 mV (45 Hz to 66 Hz)
±
0.8%rdg
±
0.2 mV (66 Hz to 1 kHz)
±
0.8% rdg
±
0.2 mV (66 Hz to 1 kHz)
±
2.0%rdg
±
0.4 mV (1 kHz to 20 kHz)
Phase
±
0.5
°
(45 Hz to 1kHz)
±
1
°
(at 50-500A,45Hz to 1kHz)
(for temperature of 23
°
C
±
5
°
C, relative humidity of 35-75%, and sinewave input)
Temperature coefficient
±
0.05%/
°
C in ranges of 5-40
°
C
Maximum allowed current
250 Arms AC (45 Hz to 1kHz)
625 Arms (45 Hz to 400Hz)
Output impedance
Approximately 6
Ω
Approximately 2.4
Ω
External magnetic field effects 0.1 A equivalent or less (at 400 A/m, 50/60 Hz)
0.2 A equivalent or less (at 400 A/m, 50/60 Hz)
Connector position effects
±
0.5% (at 20-200 A, 45 Hz to 1 kHz)
±
0.5% (at 50-500 A, 45 Hz to 1 kHz)
Used circuit voltage
600 Vrms AC maximum
Withstand voltage
3.7 kVrms AC for one minute
(across core and casing, and across core and output)
Measurable connector diameter ø30 mm maximum
Operating temperature
5 to 40
°
C, 35 to 80% RH or less (no condensation)
and humidity ranges
Storage temperature
-20 to 60
°
C, 90% RH or less (no condensation)
and humidity ranges
Operating altitude
2000m max. above sea level
External dimensions
Approx. 73 (W)
×
130(H)
×
30 (D) mm
Weight
Approx. 300g
Output cable length
Approx. 3 meters
Accessory
Instruction manual (1)
Ring markers (4 colors
×
2), L4007MG
Safety standards: The safety standards depend on the type of Current
Clamps.
• When the Current Clamp is 960 30 or 960 31
Safety standards: EN61010-1, EN61010-2-032
• Overvoltage category
II
(Max. input voltage: 600 Vrms)
• Overvoltage category
III
(Max. input voltage: 300 Vrms)
• Pollution degree 2
• When the Current Clamp is 960 30/D or 960 31/D.
(The following standards can be applied when the clamps are used with
CW140-D.)
Safety standards: UL3111-1, First Edition, UL3111-2-032, First Edition,
CAN C22.2 No.1010.1-92
• Overvoltage category
III
(Max. input voltage: 600 Vrms)
• Pollution degree 2
Содержание CW140
Страница 1: ...User s Manual CW140 CLAMP ON POWER METER IM CW140 E IM CW140 E 3rd Edition July 2001 YK ...
Страница 2: ......
Страница 14: ......
Страница 72: ......
Страница 102: ......
Страница 138: ......
Страница 152: ......
Страница 160: ......
Страница 200: ......
Страница 256: ......
Страница 274: ......
Страница 276: ......
Страница 286: ......
Страница 289: ......