IM CW140-E
11-6
11.4 Demand Measurement in Demand Measure Mode
●
Start of Demand Measurement
Even if you have finished setting the time and commanded the start of
demand measurement by an external trigger, demand measurement does
not begin unless you press the
key (status LED indicator comes on).
Demand measurement only begins when setting of the time has been
completed, the START&STOP key has been pressed, and the
mark comes on.
1
Indicates the status in which the starting time of demand measurement
is set and that the CW140 is ready for demand measurement.
2
Indicates the status in which the START&STOP key is pressed and that
the LED indicator is turned on.
3
Indicates that the START&STOP key should be pressed one more time
to begin demand measurement.
Status LED
indicator
START&STOP key
CW140
main unit
1
Location of START&STOP key
and LED indicator
2
3
LED indicator
comes on.
LED indicator
goes out.
LED indicator
comes on.
Ready for demand
(STANDBY)
Ready for
demand
(STANDBY)
Demand
in progress
Press the START&STOP
key to begin demand
measurement.
Scheduled starting time of
demand measurement
TIP
• The changing of settings is not allowed during demand measurement (viewing only).
• The setting of a time that precedes the current time is not allowed. In addition, the CW140 shows an
error message if, after time setting, the preset starting time of demand measurement has expired
before demand measurement begins.
●
End of Demand Measurement
If the end of demand measurement has been specified by setting the time or
using a timer, the CW140 automatically stops demand measurement and the
mark appears when the preset time is up.
• Forcibly stopping demand measurement before the preset time is up
Press the START&STOP key.
The following message appears.
Forcibly stops
demand measurement.
Scheduled ending
time of demand
measurement
Demand measurement
in progress
Stop demand?
ENTER: YES ESC: NO
ESC
To stop demand measurement, press the key.
To cancel the procedure for stopping demand measurement, press the key.
Содержание CW140
Страница 1: ...User s Manual CW140 CLAMP ON POWER METER IM CW140 E IM CW140 E 3rd Edition July 2001 YK ...
Страница 2: ......
Страница 14: ......
Страница 72: ......
Страница 102: ......
Страница 138: ......
Страница 152: ......
Страница 160: ......
Страница 200: ......
Страница 256: ......
Страница 274: ......
Страница 276: ......
Страница 286: ......
Страница 289: ......