10-3
IM CW140-E
Key
10
10.1 Simple Electric Energy Measurement with
Key
●
Changing the Setup Conditions
To change and save any of the Setting Conditions 1 to 4, display the screen of
that Setting Condition.
Using the
(CHANGE) key, change the conditions and confirm the
changes.
Saved parameters will be changed.
Proceed?
ENTER: YES ESC: NO
ESC
To change the parameters, press
the key.
To cancel your changes, press the
key.
●
Procedure for Changing Setup Conditions
Move through the screens "ENERGY
SET 1/3" to "ENERGY SET 3/3".
(Pressing the (NEXT) key moves
to the next screen.)
Change the V RANGE data item.
Change the A RANGE data item.
Change the WIRING data item.
Press the key.
Change the setup data items of the
Electric Energy Measure mode.
The screens are saved with the
modified setup conditions.
ESC
Pressing the key cancels the changes you made.
(The current setup conditions remain the same as before and
the display returns to a screen of the current setup conditions.)
These data items are highlighted in
sequence. Pressing any of the
to keys moves the cursor to
the next field. (If no change needs to
be made, press the key to
move to the next data item.)
This completes the procedure.
The display returns to a view of the
latest setup conditions.
TIP
• The actual ways of performing measurement and operating the meter, including integration, are the
same as those in the case of the Electric Energy Measure mode.
• The setting of the FREQUENCY SOURCE data item is the same as that defined on the SYSTEM SET
screen or the ENERGY SET 3/3 screen of the Electric Energy Measure mode. If the selected source
is not identified as an actual input on the wiring, the data item defaults to "V1". (If necessary, change
this data item when changing the setup data items of the Electric Energy Measure mode.)
Содержание CW140
Страница 1: ...User s Manual CW140 CLAMP ON POWER METER IM CW140 E IM CW140 E 3rd Edition July 2001 YK ...
Страница 2: ......
Страница 14: ......
Страница 72: ......
Страница 102: ......
Страница 138: ......
Страница 152: ......
Страница 160: ......
Страница 200: ......
Страница 256: ......
Страница 274: ......
Страница 276: ......
Страница 286: ......
Страница 289: ......