19-1
IM CW140-E
Specifications
19
Chapter 19. Specifications
19.1 Specifications
(1)
Input
Input
Input type
Ratings (ranges)
Input resistance
Maximum allowed
continuous input
A/D conversion
Range switching
Auto-range
functions
Input Voltage (V)
Resistive potential division
150, 300, 600 (V)
Approximately 1.3 M
Ω
600 Vrms
Simultaneous voltage/current input conversion, 12-bit resolution
Manual, automatic, and settings entered through PC
Current (A)
Clamp sensing
Clamp A: 20, 50, 100, 200 A
Approximately 100 k
Ω
(CW140)
Clamp A: 250 Arms
Clamp C: 625 Arms
Clamp B: 700 Arms
Range up: RMS is 110% or more of range rating, or
sampled value is approximately 300% or more of rating.
Range down: RMS is 30% or less of range rating, or
sampled value does not exceed approximately 300% of
range rating after range moves down.
(2)
Measurement functions
Parameter
Method
Frequency range
Crest factor
Effective input range
Temperature coefficient
Display update period
Voltage
Digital sampling
45 Hz to 1 kHz (harmonics mode: 45-65 Hz)
3 (for rated input)
10% to 110% of rated voltage/current range
+ 0.03% of rng/
°
C
+ 0.05% of rng/
°
C (including clamp)
Approximately 1 sec (approximately 3 sec in harmonics mode)
Current, active power, reactive power
(unbalance factor: 45-440 Hz)
Содержание CW140
Страница 1: ...User s Manual CW140 CLAMP ON POWER METER IM CW140 E IM CW140 E 3rd Edition July 2001 YK ...
Страница 2: ......
Страница 14: ......
Страница 72: ......
Страница 102: ......
Страница 138: ......
Страница 152: ......
Страница 160: ......
Страница 200: ......
Страница 256: ......
Страница 274: ......
Страница 276: ......
Страница 286: ......
Страница 289: ......