User’s
Manual
CW140
CLAMP-ON POWER METER
IM CW140-S05E
IM CW140-S05E
3rd Edition Oct. 2001 (MC)
Supplements
(1) Precautions for Safe Use of the Instrument (Page 4)
CAUTION, risk of electric shock
This symbol indicates caution and risk of electric shock.
(2) The followings are added to “
●
Service Life of NiMH Battery Pack” on page 3-16.
Dispose under regional rules when unusable.
(3) The followings are added to “(20) General specifications” on page19-12.
Environment Indoor use, Altitude up to 2000m
(4) The contents of “Ambient Temperature and Humidity” on page 3-3 and “Operating tempera-
ture and humidity ranges” on page 19-12 are changed to the followings.
Themperature 0 to 40
°
C
Maximum relative humidity 80 % RH for temperature up to 31
°
C decreasing linearly to
50 % RH relative humidity at 40
°
C.
(5) The contents of “Safety standards” on page 19-13 are changed to the followings.
Safety standards: The safety standards depend on the suffix code (type of AC adapter) of
CW140.
●
When the suffix code of CW140 is F, R or S. ( For example: CW140-S.)
Safety standards: EN61010-1, EN61010-2-031
• Overvoltage category
II
(Max.input voltage: 600Vrms)
• Overvoltage category
III
(Max.input voltage: 300Vrms)
• Pollution degree 2
●
When the suffix code of CW140 is D. (When the meter is CW140-D.)
Safety standards: UL3111-1, First Edition, CAN C22.2 No.1010.1-92
• Overvoltage category
III
Max. input voltage: 600Vrms)
• Pollution degree 2
(6) The contents of “Safety standards” on page 19-14 are changed to the followings.
Safety standards: The safety standards depend on the type of Current Clamps.
●
When the Current Clamp is 960 30 or 960 31.
Safety standards: EN61010-1, EN61010-2-032
• Overvoltage category
II
(Max.input voltage: 600Vrms)
• Overvoltage category
III
(Max.input voltage: 300Vrms)
• Pollution degree 2
●
When the Current Clamp is 960 30/D or 960 31/D.
(The following standards can be applied when the clamps are used with CW140-D.)
Safety standards: UL3111-1, First Edition, UL3111-2-032, First Edition, CAN C22.2
No.1010.1-92
• Overvoltage category
III
(Max. input voltage: 600Vrms)
• Pollution degree 2
Содержание CW140
Страница 1: ...User s Manual CW140 CLAMP ON POWER METER IM CW140 E IM CW140 E 3rd Edition July 2001 YK ...
Страница 2: ......
Страница 14: ......
Страница 72: ......
Страница 102: ......
Страница 138: ......
Страница 152: ......
Страница 160: ......
Страница 200: ......
Страница 256: ......
Страница 274: ......
Страница 276: ......
Страница 286: ......
Страница 289: ......