6
-58
L6-01 and L6-04 Set Values and LED Indications
The relationship between alarms displayed by the Digital Operator when overtorque or undertorque is
detected, and the set values in L6-01 and L6-04, is shown in the following table.
Setting Example
The following diagram shows the time chart for overtorque and undertorque detection.
•
Overtorque Detection
Set
Value
Function
LED Indications
Overtorque/
Undertorque
Detection 1
Overtorque/
Undertorque
Detection 2
0
Overtorque/undertorque detection disabled.
-
-
1
Overtorque detection only with speed matching; operation continues after
overtorque (warning).
OL3 flashes
OL4 flashes
2
Overtorque detected continuously during operation; operation continues
after overtorque (warning).
OL3 flashes
OL4 flashes
3
Overtorque detection only with speed matching; output stopped upon detec-
tion (protected operation).
OL3 lit
OL4 lit
4
Overtorque detected continuously during operation; output stopped upon
detection (protected operation).
OL3 lit
OL4 lit
5
Undertorque detection only with speed matching; operation continues after
overtorque (warning).
UL3 flashes
UL4 flashes
6
Undertorque detected continuously during operation; operation continues
after overtorque (warning).
UL3 flashes
UL4 flashes
7
Undertorque detection only with speed matching; output stopped upon
detection (protected operation).
UL3 lit
UL4 lit
8
Undertorque detected continuously during operation; output stopped upon
detection (protected operation).
UL3 lit
UL4 lit
*
*
L6-02 or L6-05
L6-03 or
L6-06
L6-03 or
L6-06
Overtorque detection 1 NO
or overtorque detection 2 NO
ON
ON
*
Overtorque detection disabled band is approximately 10% of the Inverter rated output
current (or motor rated torque).
Motor current (output torque)