6
-136
* 1. When using V/f with PG control, 0.00 to 300.00. The flux vector setting ranges are given.
* 2. When the control method changes, the factory setting is changed. The flux vector control factory settings are given. Refer to
Factory Settings that Change with the Control Method (A1-02)
.
* 3. When C6-01=1, the upper limit is 400.0.
Multi-function Contact Input Functions (H1-01 to H1-06)
C5-03
ASR pro-
portional
(P) gain 2
Usually setting is not necessary.
Set to change the rotational speed gain.
1.00 to
300.00
*1
20.00
*2
Yes
No
A
No
A
21DH
C5-04
ASR inte-
gral (I) time
2
0.000
to
10.000
0.500 s
*2
Yes
No
A
No
A
21EH
C5-05 ASR limit
Sets the upper limit for the compensa-
tion frequency for the speed control
loop (ASR) to a percentage of the max-
imum output frequency.
0.0 to
20.0
5.0%
No
No
A
No
No
21FH
C5-06
ASR pri-
mary delay
time
Sets the filter time constant for output-
ting torque references from the speed
control loop (ASR). It is set in 1-second
units.
Usually setting is not necessary.
0.000
to
0.500
0.004 s
No
No
No
No
A
220H
C5-07
ASR
switching
frequency
Sets the frequency for switching
between Proportion Gain 1, 2 and Inte-
gral Time 1, 2 in Hz units.
The multi-function input “ASR switch-
ing proportional gain” has the priority.
0.0 to
300.0
*3
0.0 Hz
No
No
No
No
A
221H
C5-08
ASR inte-
gral (I) limit
Sets the upper limit for the integral (I)
amount for the speed control loop
(ASR) to a percentage of the rated load.
0 to
400
400%
No
No
No
No
A
222H
Set-
ting
Value
Function
Control Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Flux
Vec-
tor
D
Speed control disable setting for V/f control with PG
OFF: Use speed control V/f control with PG
ON: Do not use speed control for V/f control with PG
No
Yes
No
No
E
Speed control integral reset
Enables switching between PI and P control for the speed control loop.
No
No
No
Yes
77
Speed control (ASR) proportional gain switch (switching between C5-01 and C5-03)
OFF: Use proportional gain in C5-01
ON: Use proportional gain in C5-03
No
No
No
Yes
Con-
stant
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Flux
Vec-
tor
P I
0
E1-04
Motor speed (Hz)
P=C5-01
I=C5-02
P=C5-03
I=C5-04