Connection Diagram
2-
3
Connection Diagram
The connection diagram of the Inverter is shown in
Fig 2.2
.
When using the Digital Operator, the motor can be operated by wiring only the main circuits.
Fig 2.2 Connection Diagram (Model CIMR-F7A2022 Shown Above)
Inverter
CIMR-F7A2022
P2
PC
Open collector 1
Open collector 2
Multi-function
open-collector outputs
48 VDC 50 mA max.
P1
Default: Frequency
agree signal
Default: Zero-
speed
MA
MC
MB
Error contact output
250 VAC, 10 mA min. 1 A max.
30 VAC, 10 mA min. 1 A max.
M1
M2
Multi-function contact oputput
250 VAC, 10 mA min. 1 A max.
30 VAC, 10 mA min. 1 A max.
Default: Running
signal
AC
MP
Pulse train output
Default: Output
frequency
3-phase power
200 to 240 V
50/60 Hz
R/L1
S/L2
T/L3
1MCCB
T
S
R
S5
S8
(Main speed switching) )
g)
External
baseblock command
S1
S2
S3
S4
Forward Run/Stop
Reverse Run/Stop
External fault
Fault reset
Multi-step speed reference 1
contact inputs
Multi-function
Factory
settings
IG
MEMOBUS
communications
RS-485/422
R+
R-
S-
S+
((
Braking Unit
(optional)
+ 1
+ 3
FM
AM
Multi-function analog output 1
AC
FM
E(G)
-10 to 10 V 2 mA
Default: Output frequency
0 to +10 V
Default: Output current
0 to +10 V
-10 to 10 V 2 mA
Multi-function analog output 2
Ammeter adjustment
20 k
Ω
SC
E (G)
Shield wire
connection terminal
S6
S7
Multi-step speed
reference 2
Jog frequency
selection
CN5 (NPN setting)
+24V 8mA
+24V
P
P
4 to 20 mA
0 to 10 V
0 to 10 V
Pulse train input
RP
+V
A2
A3
AC
0V
Master speed
pulse train
Frequency setting power
Master speed reference
Multi-function anlog input
Master speed reference
4 to 20 mA (250
Ω
)
[0 to 10 V (20 k
Ω
) input]
+15 V, 20 mA
0 to 10 V (20 k
Ω
)
0 to 10 V (20 k
Ω
)
Frequency
Frequency setting
adjustment
setter
External
frequency
references
2
1
3
P
-V
(15V 20mA)
Terminating
resistance
Factory setting:
Not used
PG
PG-B2
TA1
1
2
3
4
5
6
(optional)
TA3
TA2
1
Pulse monitor output
30 mA max.
Wiring distance:
d
:
30 m max.
Shieded twisted-pair
wires
H
B
G
A
F
C
D
U
U/T1
V/T2
W/T3
IM
(Ground to 100 max.)
V
W
IM
FU
FV
FW
FU
FV
FW
2MCCB
MC
Cooling fan
Motor
SA
2MCCB THRX
OFF
ON
MC
MC
SA
THRX
2
1
2
1
SA
TRX
TRX
MC
C
MC
Fault contact
MA
Thermal relay
trip contact
for motor cooling fan
A
MA
C
MC
for Braking Unit
-
Level
detector
-
-
+
0
0
B
P
Braking Resistor Unit
(optional)
4
3
2
1
+
Thermal switch contact
Thermal relay trip contact
for Braking Resistor Unit
0 to 32 kHz (3 k
Ω
)
High level: 3.5 to 13.2 V input
0 to 32 kHz (2.2 k
Ω
)
2 k
Ω
2 k
Ω
Thermal relay trip contact
Thermal switch contact
A1
Pulse A
Pulse B
1
2
3
3
4
4
Ammeter adjustment
20 k
Ω
AM