5
-70
Multi-function Selections: o2
User constants for Digital Operator key functions are shown in the following table.
o1-04
Setting unit
for fre-
quency con-
stants
related to V/
f character-
istics
Set the setting unit for frequency
reference-related constants.
0: Hz
1: min
−
1
0 or 1
0
No
No
No
No
A
503H 6-147
o1-05
LCD bright-
ness adjust-
ment
Set a smaller value to lighten
the LCD and a larger value
to darken the LCD (standard:
3).
0 to 5
3
Yes
A
A
A
A
504H
-
LCD Con-
trast
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Page
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Flux
Vec-
tor
o2-01
LOCAL/
REMOTE
key enable/
disable
Sets the Digital Operator
Local/Remote Key
0: Disabled
1: Enabled (Switches
between the Digital
Operator and the constant
settings.)
0 or 1
1
No
A
A
A
A
505H 6-147
o2-02
STOP key
during con-
trol circuit
terminal
operation
Sets the Stop Key in the run
mode.
0: Disabled (When the Run
Command is issued from
and external terminal, the
Stop Key is disabled.)
1: Enabled (Effective even
during run.)
0 or 1
1
No
A
A
A
A
506H 6-148
o2-03
User con-
stant initial
value
Clears or stores user initial
values.
0: Stores/not set
1: Begins storing (Records
the set constants as user
initial values.)
2: All clear (Clears all
recorded user initial
values)
When the set constants are
recorded as user initial val-
ues, 1110 will be set in A1-
03.
0 to 2
0
No
A
A
A
A
507H
4-17
6-148
o2-04
kVA selec-
tion
Do not set unless using a
control board from an
Inverter with a different
capacity.
0 to FF
0
*
No
A
A
A
A
508H
-
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Page
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Flux
Vec-
tor