6
-162
F5-09 Set to 1
The following table shows the code outputs.
F5-09 Set to 2
Output depends on the settings in F5-01 to F5-08.
Using an Analog Reference Board (SPEC: E or Later Only)
AI-14B provides 3 channels of bi-polar inputs with 13-bit A/D conversion accuracy (and a + sign bit). The
function of each channel is determined by the setting of F2-01.
AI-14U provides 2 channels of bi-polar inputs with 14-bit A/D conversion accuracy. Channel 1 is a voltage
input and channel 2 is a current input. The sum of channels 1 and 2 is a frequency input. F2-01 does not need
to be set for the AI-14U.
Set Value
Terminal
Number
Output Details
1: Binary code
output
TD5-TD11
bit 0
Encoded output
(Refer to table below)
TD6-TD11
bit 1
TD7-TD11
bit 2
TD8-TD11
bit 3
TD9-TD11
Zero-speed detected
TD10-TD11
Speed agreement
TD1-TD2
Operating
TD3-TD4
Minor fault
Bits 3, 2, 1,
and 0
Output Details
Bits 3, 2, 1,
and 0
Output Details
0000
No error
1000
External fault (EFxx)
0001
Overcurrent (SC, OC, GF)
1001
Control board error (CPFxx)
0010
Overvoltage (OV)
1010
Motor overload (OL1)
0011
Inverter overload (OL2)
1011
Not used
0100
Inverter overheated (OH, OH1)
1100
Power loss (UV1, UV2, or UV3)
0101
Overspeed (OS)
1101
Speed deviation (DEV)
0110
Fuse blown (PUF)
1110
PG open circuit (PGO)
0111
Dynamic braking resistor (RH)
Injection brake transistor error (RR)
1111
Not used