u
Navigating the Drive and Programming Modes
The drive is set to operate in Drive Mode when it is first powered up. Switch between display screens by using the
and
keys.
Mode
Contents
Operator Display
Description
Power Up
Frequency
Reference
(default)
- MODE -
U1-01= 0.00Hz
U1-02= 0.00Hz
U1-03= 0.00A
DRV
FREF (OPR)
Rdy
JOG
FWD
FWD/REV
LSEQ
LREF
This display screen allows the user to monitor and change the frequency reference while
Refer to The Drive, Programming, and Clock Adjustment
Note:
Use parameter o1-02 to select the data displayed when the drive is first
powered up. Setting parameter A1-02 to 6 or 7 (AOLV/PM or CLV/PM
control) will change display units to percent.
Drive Mode
Monitor Display
- MODE -
U1-01= 0.00Hz
U1-02= 0.00Hz
U1-03= 0.00A
DRV
Monitor Menu
Rdy
JOG
FWD
FWD/REV
LSEQ
LREF
Lists the monitor parameters (U
o
-
oo
parameters) available in the drive.
Press the Enter Key and then use the Up, Down, ESC, and Reset keys to navigate through
the drive monitors.
Programming
Mode
Verify Menu
- MODE -
PRG
Modified Consts
HELP
DATA
FWD
Modified
X Parameters
Lists all parameters that have been edited or changed from default settings.
Verifying Parameter Changes: Verify Menu on page 120
.
Setup Group
HELP
- MODE -
PRG
Quick Setting
DATA
FWD
A select list of parameters necessary to get the drive operating quickly.
Using the Setup Groups on page 121
.
Note:
Parameters listed in the Setup Group differ depending the Application
Refer to Application Selection on page 126
.
Parameter
Setting Mode
HELP
- MODE -
PRG
DATA
Programming
FWD
Allows the user to access and edit all parameter settings.
Auto-Tuning
Mode
HELP
- MODE -
PRG Rdy
Auto-Tuning
DATA
AUTO
FWD
Motor parameters are calculated and set automatically.
Drive Mode
Frequency
Reference
- MODE -
U1-01= 0.00Hz
U1-02= 0.00Hz
U1-03= 0.00A
DRV
FREF (OPR)
Rdy
JOG
FWD
FWD/REV
LSEQ
LREF
Returns to the frequency reference display screen.
n
Drive Mode Details
The following actions are possible in the Drive Mode:
• Run and stop the drive
• Monitor the operation status of the drive (frequency reference, output frequency, output current, output voltage, etc.)
• View information on an alarm
• View a history of alarms that have occurred
4.3 The Drive, Programming, and Clock Adjustment Modes
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
117
4
Start-Up Programming & Operation
Содержание P1000
Страница 4: ...This Page Intentionally Blank 4 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 26: ...i 2 General Safety This Page Intentionally Blank 26 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 140: ...4 11 Test Run Checklist This Page Intentionally Blank 140 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 430: ...A 4 Drive Derating Data This Page Intentionally Blank 430 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 504: ...B 16 Defaults by Drive Model This Page Intentionally Blank 504 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 568: ...D 3 UL and CSA Standards This Page Intentionally Blank 568 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 591: ...Index This Page Intentionally Blank YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual 591...
Страница 593: ......