Drive Model
Terminal
Recomm.
Gauge With
Additional
Impedance
AWG, kcmil
Screw
Size
Panduit Ring Terminal
(non-insulated)
Panduit
Recomm.
Installation
Tool
Panduit
Crimphead /
Die Part No.
Insulation Cap
Model No.
2
o
0415
R/L1, S/L2
3/0 X 2P
M12
S3/0-12R-5 (Qty. 2)
CT-720
CD-720-2
TP-080 (Qty. 2)
U/T1, V/T2, W/T3
3/0
S3/0-12R-5
TP-080
Table A.26 JST Closed-Loop Crimp Terminal Size Single-Phase With Additional Impedance
Drive Model
Terminal
Recomm.
Gauge With
Additional
Impedance
AWG, kcmil
Screw
Size
JST Ring Terminal
(non-insulated)
JST
Recomm.
Installation
Tool
JST
Crimphead /
Die Part No.
Insulation Cap
Model No.
2
o
0004
2
o
0006
2
o
0008
2
o
0010
2
o
0012
R/L1, S/L2
14
M4
R2-4
YA-4
AD-900
TP-003
U/T1, V/T2, W/T3
14
2
o
0018
2
o
0021
R/L1, S/L2
10
M4
R5.5-4
YA-4
AD-900
TP-005
U/T1, V/T2, W/T3
14
R2-4
TP-003
2
o
0030
R/L1, S/L2
10
M4
R5.5-4
YA-4
AD-900
TP-005
U/T1, V/T2, W/T3
12
2
o
0040
R/L1, S/L2
8
M4
8-4
YA-4
AD-901
TP-008
U/T1, V/T2, W/T3
12
R5.5-4
AD-900
TP-005
2
o
0056
R/L1, S/L2
6
M6
R14-6
YA-5
AD-952
TP-014
U/T1, V/T2, W/T3
6
2
o
0069
R/L1, S/L2
4
M8
R22-8
YA-5
AD-953
TP-022
U/T1, V/T2, W/T3
10
R5.5-8
YA-4
AD-900
TP-005
2
o
0081
R/L1, S/L2
3
M8
R38-8
YA-5
AD-954
TP-038
U/T1, V/T2, W/T3
8
R8-8
YA-5
AD-951
TP-008
2
o
0110
R/L1, S/L2
4
M8
R22-8
YA-5
AD-953
TP-022
U/T1, V/T2, W/T3
10
R5.5-8
YA-4
AD-900
TP-005
2
o
0138
R/L1, S/L2
2
M10
R38-10
YA-5
AD-954
TP-038
U/T1, V/T2, W/T3
8
R8-10
AD-951
TP-008
2
o
0169
R/L1, S/L2
1/0
M10
R60-10
YA-5
AD-955
TP-060
U/T1, V/T2, W/T3
6
R14-10
AD-952
TP-014
2
o
0211
R/L1, S/L2
2/0
M10
70-10
YF-1
YET-300-1
TD-323,
TD-312
TP-080
U/T1, V/T2, W/T3
1/0
R60-10
YA-5
AD-955
TP-060
2
o
0250
R/L1, S/L2
4/0
M12
100-L12
YF-1
YET-300-1
TD-324,
TD-312
TP-100
U/T1, V/T2, W/T3
3
R38-14
YA-5
AD-954
TP-038
2
o
0312
R/L1, S/L2
1/0 X 2P
M12
R60-14 (Qty. 2)
YA-5
AD-955
TP-060 (Qty. 2)
U/T1, V/T2, W/T3
1
R38-14
AD-954
TP-038
2
o
0360
R/L1, S/L2
2/0 X 2P
M12
70-14 (Qty. 2)
YF-1
YET-300-1
TD-323,
TD-312
TP-080 (Qty. 2)
U/T1, V/T2, W/T3
2/0
70-14
TP-080
2
o
0415
R/L1, S/L2
3/0 X 2P
M12
80-L12 (Qty. 2)
YF-1
YET-300-1
TD-323
TD-312
TP-080 (Qty, 2)
U/T1, V/T2, W/T3
3/0
80-L12
TP-080
A.4 Drive Derating Data
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
421
A
Specifications
Содержание P1000
Страница 4: ...This Page Intentionally Blank 4 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 26: ...i 2 General Safety This Page Intentionally Blank 26 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 140: ...4 11 Test Run Checklist This Page Intentionally Blank 140 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 430: ...A 4 Drive Derating Data This Page Intentionally Blank 430 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 504: ...B 16 Defaults by Drive Model This Page Intentionally Blank 504 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 568: ...D 3 UL and CSA Standards This Page Intentionally Blank 568 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 591: ...Index This Page Intentionally Blank YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual 591...
Страница 593: ......