No.
(Addr.
Hex)
Name
Description
Values
Page
F6-51
(3C2)
DeviceNet Communication
Speed
0: 125 kbps
1: 250 kbps
2: 500 kbps
3: Adjustable from network
4: Detect automatically
Default: 4
Range: 0 to 4
F6-52
(3C3)
DeviceNet PCA Setting
Sets the format of the data set from the DeviceNet master to the drive.
Default: 21
Min.: 0
Max.: 255
F6-53
(3C4)
DeviceNet PPA Setting
Sets the format of the data set from the drive to the DeviceNet master.
Default: 71
Min.: 0
Max.: 255
F6-54
(3C5)
DeviceNet Idle Mode Fault
Detection
0: Enabled
1: Disabled, no fault detection
2: Vendor Specific
3: Forward
4: Reverse
Default: 0
Range: 0 to 4
F6-55
(3C6)
DeviceNet Baud Rate
Monitor
Verifies the baud rate running on the network.
0: 125 kbps
1: 250 kbps
2: 500 kbps
Default: 0
Range: 0 to 2
F6-56
(3D7)
DeviceNet Speed Scaling
Sets the scaling factor for the speed monitor in DeviceNet.
Default: 0
Min.: -15
Max.: 15
F6-57
(3D8)
DeviceNet Current Scaling
Sets the scaling factor for the output current monitor in DeviceNet.
Default: 0
Min.: -15
Max.: 15
F6-58
(3D9)
DeviceNet Torque Scaling
Sets the scaling factor for the torque monitor in DeviceNet.
Default: 0
Min.: -15
Max.: 15
F6-59
(3DA)
DeviceNet Power Scaling
Sets the scaling factor for the power monitor in DeviceNet.
Default: 0
Min.: -15
Max.: 15
F6-60
(3DB)
DeviceNet Voltage Scaling
Sets the scaling factor for the voltage monitor in DeviceNet.
Default: 0
Min.: -15
Max.: 15
F6-61
(3DC)
DeviceNet Time Scaling
Sets the scaling factor for the time monitor in DeviceNet.
Default: 0
Min.: -15
Max.: 15
F6-62
(3DD)
DeviceNet Heartbeat
Interval
Sets the heartbeat interval for DeviceNet communications.
Default: 0
Min.: 0
Max.: 10
F6-63
(3DE)
DeviceNet Network MAC
ID
Saves and monitors settings 0 to 63 of F6-50 (DeviceNet MAC Address).
Default: 63
Min.: 0
Max.: 63
F6-64 to
F6-71
(3DF to
3C8)
Reserved
Reserved for Dynamic I/O Assembly Parameters.
–
–
F6-72
(081B)
PowerLink Node Address
Reserved.
–
–
F6-75
(0B20)
P1-N2 Protocol Select
Selects the protocol for the SI-J3 option card.
1: N2
2: P1
Default: 2
Range: 1, 2
–
F6-76
(0B20)
P1-N2 Comm Fault
0: Disabled
1: Enabled
Default: 1
Range: 0, 1
–
F6-77
(0B22)
P1-N2 Comm Fault Time
Sets the length of time before clearing a communication fault.
Default: 2.0 s
Min.: 0.0
Max.: 10.0
–
F6-78
(0B23)
P1-N2 Node Address
Sets the network node address.
Default: 1
Range: 0 to 255
–
B.7 F: Communication Options
450
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Содержание P1000
Страница 4: ...This Page Intentionally Blank 4 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 26: ...i 2 General Safety This Page Intentionally Blank 26 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 140: ...4 11 Test Run Checklist This Page Intentionally Blank 140 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 430: ...A 4 Drive Derating Data This Page Intentionally Blank 430 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 504: ...B 16 Defaults by Drive Model This Page Intentionally Blank 504 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 568: ...D 3 UL and CSA Standards This Page Intentionally Blank 568 YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual...
Страница 591: ...Index This Page Intentionally Blank YASKAWA SIEP YAIP1U 01C AC Drive P1000 Technical Manual 591...
Страница 593: ......