9-
25
9
T
roubleshooting
1. Error Messages
10.9 : Cannot set no axis
Code
: &H0A09
Meaning/Cause
: A no-axis setting was attempted on an axis which cannot accept.
The following axes cannot be set to no-axis.
• X and Y axes except on MULTI type robots
Action
: 1. Do not make a no-axis setting.
2. Change the axis setting.
10.10 : Cannot change axis
Code
: &H0A0A
Meaning/Cause
: Changing of an axis whose setting cannot be changed was at-
tempted.
The following axes cannot be changed.
• X and Y axes on SCARA type robots
Action
: 1. Do not change that axis.
2. Change a different axis.
10.13 : Cannot set Dualdrive
Code
: &H0A0D
Meaning/Cause
: A dual drive setting was attempted on an axis that cannot be set
to dual drive.
Action
: 1. Do not set to dual drive.
2. Change the axis setting.
10.14:
Undefined parameter found
Code
: &H0A0E
Meaning/Cause
: a. Undefined, inappropriate parameter data was written because
controller data from a different controller version was used.
b. Parameter name is wrong.
Action
: 1. Write the correct parameter data.
2. Enter the parameter name correctly.
10.21 : Sys. backup battery low voltage
Code
: &H0A15
Meaning/Cause
: a. System backup battery voltage is low.
b. System backup battery is disconnected from CPU board.
Action
: 1. Replace system backup battery.
2. Connect system backup battery securely to CPU board.
Dedicated output
: *4
Содержание RCX40
Страница 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E75 Ver 12 00 RCX40 ...
Страница 2: ......
Страница 16: ...viii MEMO ...
Страница 18: ...MEMO ...
Страница 24: ...1 6 MEMO ...
Страница 26: ...MEMO ...
Страница 34: ...MEMO ...
Страница 284: ...MEMO ...
Страница 308: ...5 24 MEMO ...
Страница 310: ...MEMO ...
Страница 318: ...6 8 MEMO ...
Страница 320: ...MEMO ...
Страница 328: ...7 8 MEMO ...
Страница 330: ...MEMO ...
Страница 336: ...MEMO ...