5-
13
5
I/O interface
1. I/O interface overview
1.8.3
Switching to AUTO mode, program reset and execution
on
AUTO mode output: DO(10)
off
on
Return-to-origin complete
output: DO(11) off
on
Robot program in-progress
output: DO(13) off
on
Program reset output: DO(14)
off
on
Interlock input: DI(11)
off
on
Program start input: DI(12)
off
on
AUTO mode input: DI(13)
off
on
Program reset input: DI(15)
off
a )
b ) c ) d ) e ) f ) g ) h ) i )
100ms or more
100ms or more
Switching to AUTO mode
a) AUTO mode input turns on.
b) AUTO mode output turns on.
c) AUTO mode input turns off after checking AUTO mode output is turned on.
Program reset
d) Program reset input turns on.
e) Program reset status output turns on.
f) Program reset input turns off after checking program reset status output is turned on.
Program execution
g) Program start input turns on.
h) Program reset status input turns off, and robot program in-progress output turns on.
i) Program start input turns off after checking robot program in-progress output is turned
on.
* Program cannot be executed when the emergency stop input and interlock input are
off.
* If the return-to-origin complete output is off, the program may not be executed,
depending on the execution level setting.
Содержание RCX40
Страница 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E75 Ver 12 00 RCX40 ...
Страница 2: ......
Страница 16: ...viii MEMO ...
Страница 18: ...MEMO ...
Страница 24: ...1 6 MEMO ...
Страница 26: ...MEMO ...
Страница 34: ...MEMO ...
Страница 284: ...MEMO ...
Страница 308: ...5 24 MEMO ...
Страница 310: ...MEMO ...
Страница 318: ...6 8 MEMO ...
Страница 320: ...MEMO ...
Страница 328: ...7 8 MEMO ...
Страница 330: ...MEMO ...
Страница 336: ...MEMO ...