4-
215
4
Operation
14. “UTILITY” mode
14.2 Enabling/disabling the sequence execution flag
To enable or disable execution of sequence programs, proceed as follows.
[Procedure]
1) Press the
F 2
(SEQUENC) key in “UTILITY” mode.
2) To enable execution of sequence programs, press the
F 1
(ENABLE) key.
To disable execution of sequence programs, press the
F 2
(DISABLE) key.
To enable DO reset during sequence program execution, press the
F 6
(RST.DO)
key.
Fig. 4-14-6 Enabling/disabling the sequence program
UTILITY
>SEQUENC
Scan Time : 10msec
Sequence : ENABLE
ENABLE
DISABLE
n
NOTE
The following conditions must be
satisfied before executing a sequence
program.
1. An object program must be made
for sequence execution.
2. Sequence execution must be
enabled.
3. DI10 contact point must be closed.
4. Operation must be in “AUTO”
mode or “MANUAL” mode.
Содержание RCX40
Страница 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E75 Ver 12 00 RCX40 ...
Страница 2: ......
Страница 16: ...viii MEMO ...
Страница 18: ...MEMO ...
Страница 24: ...1 6 MEMO ...
Страница 26: ...MEMO ...
Страница 34: ...MEMO ...
Страница 284: ...MEMO ...
Страница 308: ...5 24 MEMO ...
Страница 310: ...MEMO ...
Страница 318: ...6 8 MEMO ...
Страница 320: ...MEMO ...
Страница 328: ...7 8 MEMO ...
Страница 330: ...MEMO ...
Страница 336: ...MEMO ...