4-
92
Operation
4
11. “MANUAL” mode
11.2.9
Point data error reset
If an error “9.2 Point data destroyed” occurs in the point data, this function resets the
error and allows you to continue editing.
[Procedure]
1) Press the
F 13
(ERR. RST) key in “MANUAL>POINT” mode.
A check message appears on the guideline.
Fig. 4-11-33
MANUAL
>POINT 50% [MG][S0H0X]
————— 9.2:Point data destroyed—————————
P30 =
100.00 250.00 15.00 30.00
P31 = 50.00 100.00 15.00 10.00
P32 = 122.62 -24.54 12.35 -23.11
[POS] 50.00 100.00 5.00 10.00
Error reset OK?
YES
NO
COMNT: [ ]
2) Press the
F 4
(YES) key to reset the error.
Point data can be edited after resetting the error.
Press the
F 5
(NO) key if you want to cancel the error reset.
c
CAUTION
This function resets an error, but does
not restore the point data. A problem
is probably occurring in the point
data, so check and correct the point
data in “MANUAL>POINT>EDIT”
mode.
n
NOTE
This reset function does not work if an
error “9.3 Memory destroyed” occurs.
In this case, initialize the memory.
Содержание RCX40
Страница 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E75 Ver 12 00 RCX40 ...
Страница 2: ......
Страница 16: ...viii MEMO ...
Страница 18: ...MEMO ...
Страница 24: ...1 6 MEMO ...
Страница 26: ...MEMO ...
Страница 34: ...MEMO ...
Страница 284: ...MEMO ...
Страница 308: ...5 24 MEMO ...
Страница 310: ...MEMO ...
Страница 318: ...6 8 MEMO ...
Страница 320: ...MEMO ...
Страница 328: ...7 8 MEMO ...
Страница 330: ...MEMO ...
Страница 336: ...MEMO ...