1. Error Messages
0.6
: Program suspended by “HOLD”
Code
: &H0006
Meaning/Cause
: Program execution was interrupted by a HOLD command.
Action
: Press the
START
key to cancel hold condition and start running
the program from the next command.
0.7
: Turn on power again
Code
: &H0007
Meaning/Cause
: a. System generation was performed due to a robot change, etc.
b. Parameter was changed by data transfer.
c. System generation data was destroyed.
d. Error occurred when servo was turned ON.
Action
: Turn the controller on again.
0.8
: Try again
Code
: &H0008
Meaning/Cause
: Operation failed.
Action
: Try again.
0.9
: Arrived at break point
Code
: &H0009
Meaning/Cause
: Break point was reached during program execution.
Action
: ---
0.10 : INC. motor disconnected
Code
: &H000A
Meaning/Cause
: Return-to-origin command was attempted with the incremental
motor disconnected.
Action
: Perform absolute reset.
0.11
: ABS. motor disconnected
Code
: &H000B
Meaning/Cause
: ABS reset command was attempted on non-existent axis.
Action
: 1. Specify the correct axis.
2. Check the system generation data.
0.14 : Stop executed
Code
: &H000E
Meaning/Cause
: Stop was commanded while executing a direct command so op-
eration was stopped.
Action
: ---
0.15 : Can't execute while servo on
Code
: &H000F
Meaning/Cause
: Writing in "ALL" or "PRM" files was attempted during servo-on.
"ALL" or "PRM" files cannot be written in servo-on.
Action
: Turn off the servo before writing files.
Содержание RCX40
Страница 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E75 Ver 12 00 RCX40 ...
Страница 2: ......
Страница 16: ...viii MEMO ...
Страница 18: ...MEMO ...
Страница 24: ...1 6 MEMO ...
Страница 26: ...MEMO ...
Страница 34: ...MEMO ...
Страница 284: ...MEMO ...
Страница 308: ...5 24 MEMO ...
Страница 310: ...MEMO ...
Страница 318: ...6 8 MEMO ...
Страница 320: ...MEMO ...
Страница 328: ...7 8 MEMO ...
Страница 330: ...MEMO ...
Страница 336: ...MEMO ...