Shadow VI User Manual
1107200
Installation and Checkout
Chapter 2
page 63
Once your Shadow light curtains are tightened to their brackets and the light is green, you
are done aligning and mounting your Shadow light curtains. Go on to the checkout
procedure.
Do not begin press operation until you have completed the checkout sequence.
Diagnostic Steps to Perform
Before
Using Shadow
DANGER
!
FAILURE TO PERFORM SAFETY SYSTEM TESTS
•
Perform the final checkout sequence below when you have completed installation of your
light curtain, before operating the equipment it is connected to.
•
Operate your machinery only after your safety system meets all the requirements of the
checkout sequence.
•
Perform the final checkout sequence whenever repair, maintenance or modification is
performed on your light curtain or the machinery it is connected to.
•
Perform the “daily test” safety system checkout sequence on page 93 (in French, en
Français, page 114) every day before operating any machinery connected to Shadow safety
light curtains.
Failure to comply with these instructions will result in death or serious injury.
If your Shadow light curtain does not operate correctly, use the following diagnostic steps to
troubleshoot and correct problems. If you need help, call Wintriss Tech Support.
No Power to Unit
If your light curtain has no power, check the power fuse F1. Also check that power
connections have been done correctly. These procedures are discussed in detail in the
section "Connecting AC wiring to the control" earlier in this chapter.
The Light Curtain Is in a "Reset Required" Condition
Use the reset keyswitch to clear the “reset required” condition. If this is not successful,
power the system down, then up. Again, reset the system using the reset keyswitch.
If the “reset required” condition remains, check that you have correctly set the jumper
settings for "1 set/2 sets". This is covered in "Making settings inside the control" in this
chapter.
If the Transmitter Has No Power or Is Not Functioning
Verify your transmitter wiring
and
that the transmitter and receiver wiring is not reversed.
Add labeling to the transmitter and receiver cables in the control if you have not already done
so. Refer to "Wiring the transmitter and receiver to the control" in this chapter.
Check Power and Indicator Lights
Make sure the transmitter's amber light and red or green lights on the receiver and at the
control are both on. Also check indicators — DS3 and DS4, located in the upper right-hand
corner of the control near the power supply. DS3 and DS4 light up green to indicate that the
optic heads are receiving power.
They should be on all the time.
If they are not lit, this
Содержание Shadow VI
Страница 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Страница 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......