NOTICE
LOCKOUT MAY NOT BE REQUIRED
If light curtains are installed so they are active in all press operating modes, it may not be
necessary to lock out the press during routine die changes. Refer to the relevant safety
standards for more details.
Wiring the control into your press's emergency stop or equivalent circuitry (e.g. emergency
stop circuitry) ensures that whenever an obstruction or intrusion is detected, the press will
stop as quickly as its clutch/brake system (or other system) will permit.
Follow these instructions to connect to a traditional relay control. If you are connecting to a
PLC, refer to the instructions at the end of this section. Bring the wiring connections for the
emergency stop circuits to a convenient point so that you can tie them to the appropriate
connector. No. 16 wire is recommended for these circuits (No. 14, if local codes require it).
1. Determine how you will connect the wires from the control to your press control
emergency stop circuit. You wire the circuit at your press control. Refer to Figure 2 or
Figure 3 at the end of this manual and your press control manual or other electrical prints.
You need two wires for the emergency stop circuit.
2. As we mentioned in the previous section, if your stop circuits are 115V, the AC wiring
and stop circuits will enter the control through the same conduit (ideally, top). If the stop
circuits are 24V, then 115V goes through the top knockout and 24V goes through the
bottom left.
3. If entering from the top, make sure that you carefully dress the two wires neatly to the
left inside the control.
CAUTION
TERMINAL BLOCK TB4 WIRED INCORRECTLY
Wire stop circuits to the upper level of terminal block TB4, not the lower level. If you wire to
the lower level, this could damage components on the circuit board.
Failure to comply with these instructions could result in property damage.
4. Now locate terminal block TB4 on the control circuit board to wire the emergency stop
circuits. Notice that there are two levels at TB4 - "upper" and "lower". The stop circuits
must be wired into the upper (higher) level connector. There is also a "lower" TB4
connector on the control circuit board.
5. There is one factory-installed jumper in place on the upper TB4 connector between pins 3
and 5 (see Figure 2 or Figure 3 at the end of this manual). Make sure this jumper is firmly
installed.
Do not remove this connector or the jumpers!
There is one factory-installed jumper (XMT INT) in place on the lower TB4 connector
between pins 19 and 20 (see Figure 2 or Figure 3 at the end of this manual). Make sure
this jumper is firmly installed. Do not remove this connector! Remove this jumper only
if you use an external transmitter interrupt.
Содержание Shadow VI
Страница 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Страница 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......