Chapter 1
Introduction to Shadow VI
Safety Light Curtain
reset keyswitch
LED Indicators for
curtain clear,
floating window enabled,
curtain blocked and
reset required
(key pointed
toward "operate"
during normal
operation)
enclosure
keylock
cover latches
LIGHT CURTAIN
RESET
OPERATE
CURTAIN
CLEAR
STOP
SIGNAL
RESET
REQUIRED
FLOATING
WINDOW
Figure 1-2. Illustration of Shadow Control
How Shadow Works
WARNING
!
IMPROPER INSTALLATION
•
Connect the Shadow safety light curtain stop relays to the machine’s stop circuit. If you do
not use the stop relays, you will not have the maximum protection afforded by these light
curtains.
•
DO NOT attempt to connect Shadow safety light curtains to any control until you have
carefully read the installation instructions.
Failure to comply with these instructions could result in death or serious injury.
WARNING
!
UNPROTECTED MACHINERY MAY CONTINUE TO OPERATE
Ensure that all operators know which device(s) your Shadow safety light curtain protects and
which it does not. The press Shadow is wired to will stop when the light curtain is
interrupted and sends a stop signal to the press. However, the associated feeds and
conveyors, to which Shadow is not wired, will continue to operate after the press stops.
Failure to comply with these instructions could result in death or serious injury.
You cannot see the actual light curtain emitted by Shadow. However, the invisible curtain of
light automatically prevents access to hazardous areas while the press is operating.
Содержание Shadow VI
Страница 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Страница 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......